Standardization of breast radiotherapy structure nomenclature using transformer-based multi-modal feature learning

Standardized nomenclature for radiotherapy (RT) organs-at-risk (OARs) and target volumes (TVs) is essential for using large retrospective imaging and treatment-planning datasets. However, clinical structure names vary substantially across centres, making manual standardization time-consuming and resource-intensive. This study aims to develop a transformer-based multimodal model to automatically standardize the breast RT structure names into protocol-standard labels by combining raw clinical-use text, image features, transformer-derived spatial context, and geometric features. The model was trained and internally validated on a curated dataset from a single centre comprising 1436 breast cancer RT patients, and externally tested on 463 patients from five independent centres. During internal validation, the full multimodal model achieved a weighted F1-score of 98.08 ± 0.09%. Across the five external centres, the full model achieved weighted F1-scores ranging from 87.75% to 95.40%, with OAR accuracy reaching 100% in most centres and 96% in one centre. For primary and nodal TVs, external accuracy ranged from 80% to 97%. With reduced training data, the transformer-based model outperformed the CNN baseline when trained using 50%–80% of the available training data, with the largest difference observed at 50% training data (88.12% vs 75.36% weighted F1). These results support transformer-based multimodal learning as a scalable approach for retrospective RT nomenclature standardization, with potential application in clinical quality assurance workflows, offering a substantial reduction in manual effort and time.

Authors

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2026-06-30
DOI
https://doi.org/10.1016/j.bspc.2026.110906
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Standardization of breast radiotherapy structure nomenclature using transformer-based multi-modal feature learning

Angela Rezo, Kirsty E. Stuart, Nicholas Hardcastle, Senthilkumar Gandhidasan et al.
Biomedical Signal Processing and Control
AI in cancer detection
article

Standardization of breast radiotherapy structure nomenclature using transformer-based multi-modal feature learning

Angela Rezo, Kirsty E. Stuart, Nicholas Hardcastle, Senthilkumar Gandhidasan, Fahim Irfan Alam, Matthew Field, Shalini Vinod, J. Selvaraj, Simon Ashworth, Geoff P. Delaney, Ali Haidar, Shivani Kumar, Phillip Chlap, Janet Cui, Michael Bailey, Lois Holloway, Vicky Chin, Daniel Al Mouiee, Jonathan Sykes, Prabhakar Ramachandran, Verity Ahern
article en

Abstract

Standardized nomenclature for radiotherapy (RT) organs-at-risk (OARs) and target volumes (TVs) is essential for using large retrospective imaging and treatment-planning datasets. However, clinical structure names vary substantially across centres, making manual standardization time-consuming and resource-intensive. This study aims to develop a transformer-based multimodal model to automatically standardize the breast RT structure names into protocol-standard labels by combining raw clinical-use text, image features, transformer-derived spatial context, and geometric features. The model was trained and internally validated on a curated dataset from a single centre comprising 1436 breast cancer RT patients, and externally tested on 463 patients from five independent centres. During internal validation, the full multimodal model achieved a weighted F1-score of 98.08 ± 0.09%. Across the five external centres, the full model achieved weighted F1-scores ranging from 87.75% to 95.40%, with OAR accuracy reaching 100% in most centres and 96% in one centre. For primary and nodal TVs, external accuracy ranged from 80% to 97%. With reduced training data, the transformer-based model outperformed the CNN baseline when trained using 50%–80% of the available training data, with the largest difference observed at 50% training data (88.12% vs 75.36% weighted F1). These results support transformer-based multimodal learning as a scalable approach for retrospective RT nomenclature standardization, with potential application in clinical quality assurance workflows, offering a substantial reduction in manual effort and time.

Biomedical Signal Processing and ControlVol. 126
Australian Research Data Commons
Openalex Percentile: Top 9%
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.