Detailed High-Frequency Modeling and Experimental FRA Validation of a Multi-Section Transformer Winding

The increasing integration of renewable energy sources, high-voltage direct current (HVDC) and power-electronics-based equipment has intensified the exposure of transformer windings to high-frequency voltage components, steep-front transients and high-dv/dt stresses, highlighting the need for detailed high-frequency winding models. This study presents a high-frequency model of a six-section winding assembly corresponding to one phase of a 10 kV/0.41 kV, Dyn11, 2500 kVA distribution transformer. The winding assembly was experimentally investigated under coreless conditions using frequency response analysis (FRA) measurements over the frequency range of 20 Hz–2 MHz. Frequency-dependent resistance R(f) parameters were extracted from finite element method (FEM)-based electromagnetic field analyses, while the self- and mutual inductance matrix and the capacitance parameters were obtained from electromagnetic and electrostatic field solutions, respectively. The resulting segmented resistance–inductance–mutual inductance–capacitance (R-L-M-C) equivalent circuit model was solved in the frequency domain using Modified Nodal Analysis (MNA). Before the FRA-based validation, the low-frequency consistency of the model was checked at 50.431 Hz, where the calculated and measured magnitudes differed by only 0.1074 dB. Over the common frequency range, the model achieved a root mean square error (RMSE) of 3.09 dB and a mean absolute error (MAE) of 1.76 dB. The results show that the proposed field-extracted model can represent the overall FRA trend, the dominant attenuation region and the main resonance/anti-resonance characteristics of the winding assembly, although deviations remain around sharp resonance points.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-06-30
DOI
https://doi.org/10.3390/en19133091
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detailed High-Frequency Modeling and Experimental FRA Validation of a Multi-Section Transformer Winding

Rukiye B. Aymaz, Bora Alboyacı, Yunus Berat Demirol, İbrahim Gürsu Tekdemir
Energies
Lightning and Electromagnetic Phenomena
article

Detailed High-Frequency Modeling and Experimental FRA Validation of a Multi-Section Transformer Winding

Rukiye B. Aymaz, Bora Alboyacı, Yunus Berat Demirol, İbrahim Gürsu Tekdemir
article en

Abstract

The increasing integration of renewable energy sources, high-voltage direct current (HVDC) and power-electronics-based equipment has intensified the exposure of transformer windings to high-frequency voltage components, steep-front transients and high-dv/dt stresses, highlighting the need for detailed high-frequency winding models. This study presents a high-frequency model of a six-section winding assembly corresponding to one phase of a 10 kV/0.41 kV, Dyn11, 2500 kVA distribution transformer. The winding assembly was experimentally investigated under coreless conditions using frequency response analysis (FRA) measurements over the frequency range of 20 Hz–2 MHz. Frequency-dependent resistance R(f) parameters were extracted from finite element method (FEM)-based electromagnetic field analyses, while the self- and mutual inductance matrix and the capacitance parameters were obtained from electromagnetic and electrostatic field solutions, respectively. The resulting segmented resistance–inductance–mutual inductance–capacitance (R-L-M-C) equivalent circuit model was solved in the frequency domain using Modified Nodal Analysis (MNA). Before the FRA-based validation, the low-frequency consistency of the model was checked at 50.431 Hz, where the calculated and measured magnitudes differed by only 0.1074 dB. Over the common frequency range, the model achieved a root mean square error (RMSE) of 3.09 dB and a mean absolute error (MAE) of 1.76 dB. The results show that the proposed field-extracted model can represent the overall FRA trend, the dominant attenuation region and the main resonance/anti-resonance characteristics of the winding assembly, although deviations remain around sharp resonance points.

EnergiesVol. 19(13)
Bursa Technical University (TR), Kocaeli Üniversitesi (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Affordable and clean energy
Openalex Percentile: Top 8%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.