Dominant-Mode-Based SCR-Adaptive SG-PSO Tuning for LVRT Recovery of PMSG Wind Turbines in Weak Grids

Transient instability during the low-voltage ride-through (LVRT) recovery of permanent magnet synchronous generator (PMSG) wind turbines is strongly influenced by weak-grid interactions, while the quantitative relationship among grid strength, control parameters, and recovery performance remains insufficiently understood. This paper develops a small-signal transient recovery characteristic matrix for a grid-connected PMSG system by incorporating the dynamic interactions among the phase-locked loop (PLL), inner current loop, DC-link voltage loop, and grid-side inductance. Dominant-mode and root-locus analyses are employed to investigate how variations in the short-circuit ratio (SCR) affect dominant eigenvalue trajectories and the sensitivities of six PI control parameters. Based on the identified dynamic mechanisms, an SCR-adaptive sensitivity-guided particle swarm optimization (SG-PSO) method is proposed for coordinated PI parameter tuning. The proposed approach introduces SCR-dependent damping constraints and physical feasibility constraints, while normalized real-part eigenvalue sensitivities are utilized to guide the optimization process toward the most influential control parameters. Comparative simulation results demonstrate that, under SCR = 1.5, SG-PSO reduces the point of common coupling (PCC) voltage overshoot to 1.4% and shortens the recovery time to 58 ms, achieving better transient recovery indices than conventional PSO and OOBO-PI under the same simulation and constraint settings. Under SCR = 2.5, the recovery time is further reduced to 46 ms while maintaining a low overshoot of 0.9%. Additional robustness tests under parameter uncertainties and fault-condition variations further support the effectiveness and adaptability of the proposed method. The results indicate that the proposed SG-PSO framework provides an effective solution for enhancing LVRT recovery performance of PMSG wind turbines operating in weak-grid environments.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-06-29
DOI
https://doi.org/10.3390/en19133081
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dominant-Mode-Based SCR-Adaptive SG-PSO Tuning for LVRT Recovery of PMSG Wind Turbines in Weak Grids

Butian Chen, Zixuan Liu, Xinghao Feng, Xiao Han et al.
Energies
Wind Turbine Control Systems
article

Dominant-Mode-Based SCR-Adaptive SG-PSO Tuning for LVRT Recovery of PMSG Wind Turbines in Weak Grids

Butian Chen, Zixuan Liu, Xinghao Feng, Xiao Han, Tong Huang
article en

Abstract

Transient instability during the low-voltage ride-through (LVRT) recovery of permanent magnet synchronous generator (PMSG) wind turbines is strongly influenced by weak-grid interactions, while the quantitative relationship among grid strength, control parameters, and recovery performance remains insufficiently understood. This paper develops a small-signal transient recovery characteristic matrix for a grid-connected PMSG system by incorporating the dynamic interactions among the phase-locked loop (PLL), inner current loop, DC-link voltage loop, and grid-side inductance. Dominant-mode and root-locus analyses are employed to investigate how variations in the short-circuit ratio (SCR) affect dominant eigenvalue trajectories and the sensitivities of six PI control parameters. Based on the identified dynamic mechanisms, an SCR-adaptive sensitivity-guided particle swarm optimization (SG-PSO) method is proposed for coordinated PI parameter tuning. The proposed approach introduces SCR-dependent damping constraints and physical feasibility constraints, while normalized real-part eigenvalue sensitivities are utilized to guide the optimization process toward the most influential control parameters. Comparative simulation results demonstrate that, under SCR = 1.5, SG-PSO reduces the point of common coupling (PCC) voltage overshoot to 1.4% and shortens the recovery time to 58 ms, achieving better transient recovery indices than conventional PSO and OOBO-PI under the same simulation and constraint settings. Under SCR = 2.5, the recovery time is further reduced to 46 ms while maintaining a low overshoot of 0.9%. Additional robustness tests under parameter uncertainties and fault-condition variations further support the effectiveness and adaptability of the proposed method. The results indicate that the proposed SG-PSO framework provides an effective solution for enhancing LVRT recovery performance of PMSG wind turbines operating in weak-grid environments.

EnergiesVol. 19(13)
Nanjing Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 11%
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.