Application of MINICS software in measuring parameters of femoral neck fractures and its clinical significance

Objective: This study aimed to investigate the application of MIMICS software in measuring femoral neck fracture (FNF) parameters and its clinical significance.Method: Computed tomography data from 72 patients with FNFs were used to reconstruct three-dimensional (3D) models using MIMICS.The FNFs were divided into valgus and bowing groups based on the coronal femoral head-neck angle.A simulated sphere identified the center of the femoral head, and a 3D coordinate system was established.Statistical analyses were performed.Results: The valgus group showed more lateral x-axis and upward z-axis displacement (both p < 0.01).The medial x-axis and downward z-axis displacement distances were larger in the bowing group (both p < 0.01).Strong positive correlations were found between the horizontal head tilt angle and head spacing, spatial headneck angle and y-axis displacement distance (all r s > 0.89, p < 0.01).Conclusions: MIMICS-based FNF parameter measurement accurately describes spatial characteristics post-fracture, providing guidance for FNF treatment and evaluation.

Authors

Institutions

Publication Details

Journal
Cirugía y Cirujanos (English Edition)
Published
2026-06-29
DOI
https://doi.org/10.24875/cirue.m24000927
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of MINICS software in measuring parameters of femoral neck fractures and its clinical significance

Ruyi Zhang, Peng Su, Yi Zhang, Feng Liu et al.
Cirugía y Cirujanos (English Edition)
Hip and Femur Fractures
article

Application of MINICS software in measuring parameters of femoral neck fractures and its clinical significance

Ruyi Zhang, Peng Su, Yi Zhang, Feng Liu, Lichao Zhang
article en

Abstract

Objective: This study aimed to investigate the application of MIMICS software in measuring femoral neck fracture (FNF) parameters and its clinical significance.Method: Computed tomography data from 72 patients with FNFs were used to reconstruct three-dimensional (3D) models using MIMICS.The FNFs were divided into valgus and bowing groups based on the coronal femoral head-neck angle.A simulated sphere identified the center of the femoral head, and a 3D coordinate system was established.Statistical analyses were performed.Results: The valgus group showed more lateral x-axis and upward z-axis displacement (both p < 0.01).The medial x-axis and downward z-axis displacement distances were larger in the bowing group (both p < 0.01).Strong positive correlations were found between the horizontal head tilt angle and head spacing, spatial headneck angle and y-axis displacement distance (all r s > 0.89, p < 0.01).Conclusions: MIMICS-based FNF parameter measurement accurately describes spatial characteristics post-fracture, providing guidance for FNF treatment and evaluation.

Cirugía y Cirujanos (English Edition)Vol. 94(2)
Beijing Shijingshan Hospital (CN)
Gender equality
Openalex Percentile: Top 6%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application of MINICS software in measuring parameters of femoral neck fractures and its clinical significance — Ruyi Zhang, Peng Su, et al. · Cirugía y Cirujanos (English Edition) (2026) | TGRS Research Map | TGRS