High-speed and high-sensitivity multi-gas detection based on parallel heterodyne LITES sensor

Abstract A parallel heterodyne light-induced thermoelastic spectroscopy (PH-LITES) sensor is proposed for high-speed and high-sensitivity multi-gas detection for the first time. Within the collaborative signal enhancement architecture (CSEA), high sensitivity and high-speed detection are achieved at the physical layer. A self-designed cylindrical multi-pass cell (MPC) with a recorded high optical path length to volume ratio (OPL/V = 37.4 cm –2 ) and a four‑tine quartz tuning fork (QTF) with a low resonant frequency ( f 0 = ~7.9 kHz) work synergistically to enhance detection responsivity, establishing a robust foundation for highly sensitive detection of low-concentration gas mixtures. High‑speed capability is enabled by parallel heterodyne modulation, where a single QTF is excited to generate a composite transient response signal, allowing for the rapid, simultaneous acquisition of spectral information from multiple gases. At the information layer, intelligent processing is implemented via a collaborative intelligent processing architecture (CIPA) integrating convolutional neural networks (CNN), a hybrid attention mechanism (HAM), and bidirectional long short-term memory (BiLSTM). The CNN-HAM-BiLSTM architecture performs feature extraction, attention-based enhancement, and temporal modeling to enable accurate concentration retrieval from the parallel spectra derived from a single QTF output. Experimental validation using methane (CH 4 ) and acetylene (C 2 H 2 ) achieved minimum detection limits (MDLs) of 378 ppb and 285 ppb, respectively, within a 4 s scanning time. The proposed system offers an efficient solution for applications requiring rapid and sensitive multi-gas detection.

Authors

Institutions

Publication Details

Journal
Light Science & Applications
Published
2026-06-29
DOI
https://doi.org/10.1038/s41377-026-02385-4
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-speed and high-sensitivity multi-gas detection based on parallel heterodyne LITES sensor

Yongkang Dong, Jinfeng Hou, Yufei Ma, Haiyue Sun et al.
Light Science & Applications
Spectroscopy and Laser Applications
article

High-speed and high-sensitivity multi-gas detection based on parallel heterodyne LITES sensor

Yongkang Dong, Jinfeng Hou, Yufei Ma, Haiyue Sun, Yuanzhi Wang, Shunda Qiao, Y Q He, Chu Zhang
article en

Abstract

Abstract A parallel heterodyne light-induced thermoelastic spectroscopy (PH-LITES) sensor is proposed for high-speed and high-sensitivity multi-gas detection for the first time. Within the collaborative signal enhancement architecture (CSEA), high sensitivity and high-speed detection are achieved at the physical layer. A self-designed cylindrical multi-pass cell (MPC) with a recorded high optical path length to volume ratio (OPL/V = 37.4 cm –2 ) and a four‑tine quartz tuning fork (QTF) with a low resonant frequency ( f 0 = ~7.9 kHz) work synergistically to enhance detection responsivity, establishing a robust foundation for highly sensitive detection of low-concentration gas mixtures. High‑speed capability is enabled by parallel heterodyne modulation, where a single QTF is excited to generate a composite transient response signal, allowing for the rapid, simultaneous acquisition of spectral information from multiple gases. At the information layer, intelligent processing is implemented via a collaborative intelligent processing architecture (CIPA) integrating convolutional neural networks (CNN), a hybrid attention mechanism (HAM), and bidirectional long short-term memory (BiLSTM). The CNN-HAM-BiLSTM architecture performs feature extraction, attention-based enhancement, and temporal modeling to enable accurate concentration retrieval from the parallel spectra derived from a single QTF output. Experimental validation using methane (CH 4 ) and acetylene (C 2 H 2 ) achieved minimum detection limits (MDLs) of 378 ppb and 285 ppb, respectively, within a 4 s scanning time. The proposed system offers an efficient solution for applications requiring rapid and sensitive multi-gas detection.

Light Science & ApplicationsVol. 15(1)
Harbin Institute of Technology (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Natural Science Foundation of Heilongjiang Province, Fundamental Research Funds for the Central Universities
Industry, innovation and infrastructure
Openalex Percentile: Top 13%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.