An Experimental Study on the Effectiveness of Fire Dampers in Kitchen Exhaust Ducts

This study experimentally investigated the effectiveness of fire damper installation and fan operation for suppressing the spread of fire through exhaust ducts during cooking-related fires. Two types of duct systems, barbecue table and kitchen cooking exhaust ducts with different diameters, were constructed, and fire dampers were installed inside the ducts. The effects of fire damper operation, number of installed dampers, and fan operating conditions on the internal temperature of the ducts were analyzed. The results showed that the operation of fire dampers physically blocked the propagation path of heat within the ducts, whereas the operation of fan reduced the heat accumulation inside the ducts. Under combined fan and fire damper operation, a temporary temperature increase occurred immediately after damper activation. However, the maximum temperature in the section between the fan and fire damper was approximately 47.9 °C, which was approximately 50% lower than the maximum temperature of 97.6 °C observed when the fire damper was not operating. In addition, in sediment fire experiments, although a temporary backflow of heat occurred after damper activation, the overall temperature increase was mitigated.

Authors

Institutions

Publication Details

Journal
Fire Science and Engineering
Published
2026-06-29
DOI
https://doi.org/10.7731/kifse.d5b1c433
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Experimental Study on the Effectiveness of Fire Dampers in Kitchen Exhaust Ducts

Tae-Hee Park, Tae‐Dong Kim, Tae-Sun Kim, Ji-Hyun Yang et al.
Fire Science and Engineering
Fire dynamics and safety research
article

An Experimental Study on the Effectiveness of Fire Dampers in Kitchen Exhaust Ducts

Tae-Hee Park, Tae‐Dong Kim, Tae-Sun Kim, Ji-Hyun Yang, Jin-Suk Kwon
article en

Abstract

This study experimentally investigated the effectiveness of fire damper installation and fan operation for suppressing the spread of fire through exhaust ducts during cooking-related fires. Two types of duct systems, barbecue table and kitchen cooking exhaust ducts with different diameters, were constructed, and fire dampers were installed inside the ducts. The effects of fire damper operation, number of installed dampers, and fan operating conditions on the internal temperature of the ducts were analyzed. The results showed that the operation of fire dampers physically blocked the propagation path of heat within the ducts, whereas the operation of fan reduced the heat accumulation inside the ducts. Under combined fan and fire damper operation, a temporary temperature increase occurred immediately after damper activation. However, the maximum temperature in the section between the fan and fire damper was approximately 47.9 °C, which was approximately 50% lower than the maximum temperature of 97.6 °C observed when the fire damper was not operating. In addition, in sediment fire experiments, although a temporary backflow of heat occurred after damper activation, the overall temperature increase was mitigated.

Fire Science and EngineeringVol. 40(3)
New York City Fire Department (US), National Research Institute of Fire and Disaster (JP)
Openalex Percentile: Top 7%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.