Blast Resistance of RC Slabs Strengthened with Concrete-Based Protective Layers Under Contact Explosion

This study investigates the blast-protective performance of RC slab strengthened on the blast face with various concrete protective layers under contact-detonation loading. The research focuses on analyzing shock wave propagation characteristics, peak pressures at measurement points, energy absorption capacities of the protective layers, the development of damage, and the governing failure mechanisms of the RC slab. The protective layers used for structural reinforcement include Steel Fiber-Reinforced Cellular Concrete (SFR-CC), Asphalt Concrete (AC), Rubberized Concrete (RBC), and Foamed Concrete (FC). Among these, the maximum support rotation angle of the structure strengthened with the SFR-CC concrete layer (T-1) is 0.20°, indicating significantly less damage and deformation compared to other protective schemes. Based on the damage coefficient calculated from the remaining sectional moment of inertia of the protected RC slabs, the destruction grades of the structures at different concrete protective schemes were classified. Among these, the SFR-CC layer exhibits the most effective attenuation of shock wave peak pressure. Additionally, the maximum support rotation angle of the structure strengthened with the SFR-CC concrete layer is 0.20°, indicating significantly less damage and deformation compared to other protective schemes. Damage grades were assigned according to a coefficient derived from the residual sectional moment of inertia of the protected RC slabs. The SFR-CC configuration (T-1) gives the lowest damage index, 0.178, approximately 64.5% below that of the NC scheme, and is classified as slight damage. In contrast to the severe damage sustained by the protected RC slabs strengthened with the NC concrete scheme, those strengthened with the AC, RBC, and FC protective layer schemes exhibit only a moderate damage grade. Empirical formulas predicting the damage index of protected structures under the combined effects of varying blast charges and concrete layer thicknesses were further developed for rapid damage assessment.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-06-29
DOI
https://doi.org/10.3390/buildings16132609
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Blast Resistance of RC Slabs Strengthened with Concrete-Based Protective Layers Under Contact Explosion

Shubo Dai, Changhui Zhang, Ran Song, Jinlei Zheng et al.
Buildings
Structural Response to Dynamic Loads
article

Blast Resistance of RC Slabs Strengthened with Concrete-Based Protective Layers Under Contact Explosion

Shubo Dai, Changhui Zhang, Ran Song, Jinlei Zheng, Meili Meng, Kelei Cao
article en

Abstract

This study investigates the blast-protective performance of RC slab strengthened on the blast face with various concrete protective layers under contact-detonation loading. The research focuses on analyzing shock wave propagation characteristics, peak pressures at measurement points, energy absorption capacities of the protective layers, the development of damage, and the governing failure mechanisms of the RC slab. The protective layers used for structural reinforcement include Steel Fiber-Reinforced Cellular Concrete (SFR-CC), Asphalt Concrete (AC), Rubberized Concrete (RBC), and Foamed Concrete (FC). Among these, the maximum support rotation angle of the structure strengthened with the SFR-CC concrete layer (T-1) is 0.20°, indicating significantly less damage and deformation compared to other protective schemes. Based on the damage coefficient calculated from the remaining sectional moment of inertia of the protected RC slabs, the destruction grades of the structures at different concrete protective schemes were classified. Among these, the SFR-CC layer exhibits the most effective attenuation of shock wave peak pressure. Additionally, the maximum support rotation angle of the structure strengthened with the SFR-CC concrete layer is 0.20°, indicating significantly less damage and deformation compared to other protective schemes. Damage grades were assigned according to a coefficient derived from the residual sectional moment of inertia of the protected RC slabs. The SFR-CC configuration (T-1) gives the lowest damage index, 0.178, approximately 64.5% below that of the NC scheme, and is classified as slight damage. In contrast to the severe damage sustained by the protected RC slabs strengthened with the NC concrete scheme, those strengthened with the AC, RBC, and FC protective layer schemes exhibit only a moderate damage grade. Empirical formulas predicting the damage index of protected structures under the combined effects of varying blast charges and concrete layer thicknesses were further developed for rapid damage assessment.

BuildingsVol. 16(13)
North China University of Water Resources and Electric Power (CN), China Railway Construction Corporation (China) (CN), China Railway Design Corporation (China) (CN)
National Natural Science Foundation of China, Natural Science Foundation of Henan Province
Sustainable cities and communities
Openalex Percentile: Top 11%
Structural Response to Dynamic Loads
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.