Safety, efficacy, pharmacokinetics, and mechanisms of novel <sup>10</sup> B‐boronophenylalanine combined with a radio‐frequency quadrupole accelerator in boron neutron capture therapy: A preclinical study in head and neck squamous cell carcinoma

Abstract Background and Purpose Boron neutron capture therapy (BNCT) is an emerging binary‐targeted radiotherapeutic modality with promising potential for treating recurrent or refractory head and neck squamous cell carcinoma. We comprehensively evaluated the safety, efficacy, pharmacokinetics, and mechanisms of action of a novel 10 B‐boronophenylalanine ( 10 B‐BPA) combined with a radio‐frequency quadrupole (RFQ) accelerator‐based neutron source using systematic preclinical experiments. Methods This systematic preclinical study began by evaluating the drug's in vivo pharmacokinetics, tumor accumulation specificity, maximum tolerated dose, and systemic toxicity to verify its safety profile. Subsequently, its antitumor efficacy was assessed through dose‐dependent experiments, and the cellular and molecular mechanisms of BNCT treatment were investigated. Results The novel 10 B‐BPA exhibited rapid and highly specific tumor accumulation, achieving a stable tumor‐to‐blood ratio of approximately 3.5. The treatment resulted in dose‐dependent tumor regression without inducing systemic toxicity, with a maximum tolerated dose of more than 1000 mg/kg. Mechanistic investigations revealed that BNCT triggered a hypoxic stress response, leading to a substantial accumulation of reactive oxygen species and induced DNA double‐strand breaks. This metabolic crisis subsequently activated the hypoxia‐inducible factor‐1 alpha and nuclear factor kappa‐B signaling axes during apoptosis. Conclusions The novel 10 B‐BPA/RFQ accelerator‐based neutron source BNCT system demonstrates favorable safety, potent antitumor activity, and multi‐target molecular regulatory mechanisms. These findings provide a solid foundation for its clinical translation.

Authors

Institutions

Publication Details

Journal
Precision Radiation Oncology
Published
2026-06-28
DOI
https://doi.org/10.1002/pro6.70075
Primary Topic
Boron Compounds in Chemistry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safety, efficacy, pharmacokinetics, and mechanisms of novel 10 B‐boronophenylalanine combined with a radio‐frequency quadrupole accelerator in boron neutron capture therapy: A preclinical study in head and neck squamous cell carcinoma

Shaobo Huang, Qiubo Chu, Linxuan Huang, Junyan Li et al.
Precision Radiation Oncology
Boron Compounds in Chemistry
article

Safety, efficacy, pharmacokinetics, and mechanisms of novel 10 B‐boronophenylalanine combined with a radio‐frequency quadrupole accelerator in boron neutron capture therapy: A preclinical study in head and neck squamous cell carcinoma

Shaobo Huang, Qiubo Chu, Linxuan Huang, Junyan Li, Ling Xu, Huafu Ouyang, Zhigang Liu, Lin Li, Minhua Fan, Zhaoyuan Zhang, Yannan Zheng, Zhenting Ma, Gui Bao, Huijie Yan
article en

Abstract

Abstract Background and Purpose Boron neutron capture therapy (BNCT) is an emerging binary‐targeted radiotherapeutic modality with promising potential for treating recurrent or refractory head and neck squamous cell carcinoma. We comprehensively evaluated the safety, efficacy, pharmacokinetics, and mechanisms of action of a novel 10 B‐boronophenylalanine ( 10 B‐BPA) combined with a radio‐frequency quadrupole (RFQ) accelerator‐based neutron source using systematic preclinical experiments. Methods This systematic preclinical study began by evaluating the drug's in vivo pharmacokinetics, tumor accumulation specificity, maximum tolerated dose, and systemic toxicity to verify its safety profile. Subsequently, its antitumor efficacy was assessed through dose‐dependent experiments, and the cellular and molecular mechanisms of BNCT treatment were investigated. Results The novel 10 B‐BPA exhibited rapid and highly specific tumor accumulation, achieving a stable tumor‐to‐blood ratio of approximately 3.5. The treatment resulted in dose‐dependent tumor regression without inducing systemic toxicity, with a maximum tolerated dose of more than 1000 mg/kg. Mechanistic investigations revealed that BNCT triggered a hypoxic stress response, leading to a substantial accumulation of reactive oxygen species and induced DNA double‐strand breaks. This metabolic crisis subsequently activated the hypoxia‐inducible factor‐1 alpha and nuclear factor kappa‐B signaling axes during apoptosis. Conclusions The novel 10 B‐BPA/RFQ accelerator‐based neutron source BNCT system demonstrates favorable safety, potent antitumor activity, and multi‐target molecular regulatory mechanisms. These findings provide a solid foundation for its clinical translation.

Precision Radiation Oncology
Hainan University (CN), China Spallation Neutron Source (CN), Dongguan People’s Hospital (CN), Southern Medical University Shenzhen Hospital (CN), Hainan Agricultural School (CN)
Good health and well-being
Openalex Percentile: Top 6%
Boron Compounds in Chemistry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.