In Vivo Monitoring of Thrombo‐Inflammatory Biomarkers via Molecularly Imprinted Polymer‐Integrated Hydrogel Microneedles

ABSTRACT Thrombotic disorders are a leading cause of cardiovascular mortality worldwide; however, real‐time, point‐of‐care monitoring technologies for timely detection of evolving coagulopathies remain inaccessible. Wearable, minimally invasive tracking of thrombo‐inflammatory activity could enable earlier risk assessment and more effective therapy monitoring than conventional episodic blood tests. Here, we present a reagent‐free, wearable electrochemical platform that integrates an on‐chip Prussian Blue (PB) redox transducer with a signal‐off molecularly imprinted polymer (MIP) layer and a biocompatible hydrogel microneedle (HMN) array for interstitial fluid (ISF) sampling, enabling direct electrochemical detection of thrombo‐inflammatory biomarkers. The electrochemical PB/MIP (e‐MIP) biosensor was configured to quantify thrombin (thrombotic biomarker) as well as interleukin‐6 (IL‐6) and tumor necrosis factor‐α (TNF‐α) (inflammatory biomarkers) directly in dermal ISF extracted via the integrated HMNs. The wearable e‐MIP was characterized in vitro and ex vivo, where porcine skin tests preserved linearity and achieved limits of detection (LODs) of 0.26 ng mL − 1 for thrombin and ≤ 0.41 pg mL − 1 for IL‐6 and TNF‐α, confirming sensitive performance in a skin model. Also, selectivity studies against potential interferents (e.g., prothrombin or cardiac troponins) were conducted to assess the possible cross‐reactivity. in vivo, HMN‐integrated patches applied to lipopolysaccharide (LPS)–challenged rats sampled ISF and delivered it to the e‐MIP, which captured the rise‐and‐fall kinetics of thrombin and IL‐6 over 0–24 h. The results were validated against parallel enzyme‐linked immunosorbent assays (ELISAs) performed on plasma collected at corresponding time points. Its versatile architecture and demonstrated in vivo performance position it as a promising platform that can enable early thrombotic risk assessment and therapeutic monitoring, with potential applications in personalized cardiovascular management following clinical validation.

Authors

Institutions

Publication Details

Journal
Advanced Materials
Published
2026-06-29
DOI
https://doi.org/10.1002/adma.202521589
Primary Topic
Advancements in Transdermal Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vivo Monitoring of Thrombo‐Inflammatory Biomarkers via Molecularly Imprinted Polymer‐Integrated Hydrogel Microneedles

Sanjana Srikant, Roozbeh Siavash Moakhar, Fatemeh Keyvani, Joe Quadrilatero et al.
Advanced Materials
Advancements in Transdermal Drug Delivery
article

In Vivo Monitoring of Thrombo‐Inflammatory Biomarkers via Molecularly Imprinted Polymer‐Integrated Hydrogel Microneedles

Sanjana Srikant, Roozbeh Siavash Moakhar, Fatemeh Keyvani, Joe Quadrilatero, Peyman GhavamiNejad, Mackenzie Graham, Sara Mahshid, Sripadh Guptha Yedire, Mahla Poudineh, Arash Khorrami Jahromi, Mahmoud Ayman Saleh, Sajad Shiekh
article en

Abstract

ABSTRACT Thrombotic disorders are a leading cause of cardiovascular mortality worldwide; however, real‐time, point‐of‐care monitoring technologies for timely detection of evolving coagulopathies remain inaccessible. Wearable, minimally invasive tracking of thrombo‐inflammatory activity could enable earlier risk assessment and more effective therapy monitoring than conventional episodic blood tests. Here, we present a reagent‐free, wearable electrochemical platform that integrates an on‐chip Prussian Blue (PB) redox transducer with a signal‐off molecularly imprinted polymer (MIP) layer and a biocompatible hydrogel microneedle (HMN) array for interstitial fluid (ISF) sampling, enabling direct electrochemical detection of thrombo‐inflammatory biomarkers. The electrochemical PB/MIP (e‐MIP) biosensor was configured to quantify thrombin (thrombotic biomarker) as well as interleukin‐6 (IL‐6) and tumor necrosis factor‐α (TNF‐α) (inflammatory biomarkers) directly in dermal ISF extracted via the integrated HMNs. The wearable e‐MIP was characterized in vitro and ex vivo, where porcine skin tests preserved linearity and achieved limits of detection (LODs) of 0.26 ng mL − 1 for thrombin and ≤ 0.41 pg mL − 1 for IL‐6 and TNF‐α, confirming sensitive performance in a skin model. Also, selectivity studies against potential interferents (e.g., prothrombin or cardiac troponins) were conducted to assess the possible cross‐reactivity. in vivo, HMN‐integrated patches applied to lipopolysaccharide (LPS)–challenged rats sampled ISF and delivered it to the e‐MIP, which captured the rise‐and‐fall kinetics of thrombin and IL‐6 over 0–24 h. The results were validated against parallel enzyme‐linked immunosorbent assays (ELISAs) performed on plasma collected at corresponding time points. Its versatile architecture and demonstrated in vivo performance position it as a promising platform that can enable early thrombotic risk assessment and therapeutic monitoring, with potential applications in personalized cardiovascular management following clinical validation.

Advanced Materials
University of Waterloo (CA), McGill University (CA)
Canada Foundation for Innovation, Natural Sciences and Engineering Research Council of Canada
Good health and well-being
Openalex Percentile: Top 10%
Advancements in Transdermal Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.