Proving Use Requirements of Interactive Systems with Remote Monitoring and Control Capabilities EICS024

A generation of interoperable devices is emerging in control systems. Devices can be controlled by users at multiple levels. The devices that are controlled may be certified as safe by their vendors, but new issues may arise from their integration and remote use, as new interaction pathways will be enabled that are simply not possible when the device is used as a stand-alone system. This paper is concerned with modelling concrete interfaces that are designed to enable use of these systems. It builds on previous work concerned with proving use-centred safety properties across the interoperable system. The concern of this paper however is describing the relationship between an abstract model and a concrete interface that reflects more concretely the tasks that the users are intended to perform. In the example used in this paper, a menu interface is built on top of the abstract interface. The primary concern of the paper is describing the relationship between the abstract interface and the specified concrete interface. Properties of the interface that were discussed in previous work are proved of the concrete interface. This paper uses, as an example, use-centred safety properties of integrated clinical environments for remote medical care. Four properties are considered briefly: consistency , completeness , feedback and reversibility with an understanding of the tasks that users may perform. More detail will be given to the first two with a particular focus on the relation between the abstract interaction model and a concrete menu based model. The properties are formalised in the language of the PVS verification system. They are mechanically verified using the PVS proof assistant for a model of a realistic prototype of an integrated clinical environment. The presented analysis is intended to be performed during system design and development, and before the actual system is deployed, to increase confidence that the design complies with important use-centred safety properties that capture design guidelines discussed in usability engineering standards. It is envisaged that such an analysis could help inform a safety assessment of the integrated system.

Authors

Institutions

Publication Details

Journal
Proceedings of the ACM on Human-Computer Interaction
Published
2026-06-29
DOI
https://doi.org/10.1145/3816776
Primary Topic
Healthcare Technology and Patient Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proving Use Requirements of Interactive Systems with Remote Monitoring and Control Capabilities EICS024

José Creissac Campos, Paolo Masci, Michael D. Harrison
Proceedings of the ACM on Human-Computer Interaction
Healthcare Technology and Patient Monitoring
article

Proving Use Requirements of Interactive Systems with Remote Monitoring and Control Capabilities EICS024

José Creissac Campos, Paolo Masci, Michael D. Harrison
article en

Abstract

A generation of interoperable devices is emerging in control systems. Devices can be controlled by users at multiple levels. The devices that are controlled may be certified as safe by their vendors, but new issues may arise from their integration and remote use, as new interaction pathways will be enabled that are simply not possible when the device is used as a stand-alone system. This paper is concerned with modelling concrete interfaces that are designed to enable use of these systems. It builds on previous work concerned with proving use-centred safety properties across the interoperable system. The concern of this paper however is describing the relationship between an abstract model and a concrete interface that reflects more concretely the tasks that the users are intended to perform. In the example used in this paper, a menu interface is built on top of the abstract interface. The primary concern of the paper is describing the relationship between the abstract interface and the specified concrete interface. Properties of the interface that were discussed in previous work are proved of the concrete interface. This paper uses, as an example, use-centred safety properties of integrated clinical environments for remote medical care. Four properties are considered briefly: consistency , completeness , feedback and reversibility with an understanding of the tasks that users may perform. More detail will be given to the first two with a particular focus on the relation between the abstract interaction model and a concrete menu based model. The properties are formalised in the language of the PVS verification system. They are mechanically verified using the PVS proof assistant for a model of a realistic prototype of an integrated clinical environment. The presented analysis is intended to be performed during system design and development, and before the actual system is deployed, to increase confidence that the design complies with important use-centred safety properties that capture design guidelines discussed in usability engineering standards. It is envisaged that such an analysis could help inform a safety assessment of the integrated system.

Proceedings of the ACM on Human-Computer InteractionVol. 10(4)
PFP Cybersecurity (United States) (US), INESC TEC (PT), Mass General Brigham (US), Newcastle University (GB), University of Minho (PT)
Openalex Percentile: Top 6%
Healthcare Technology and Patient Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.