Utilization and characterization of the Medtronic Mosaic in a relevant chronic ovine model of surgical tricuspid valve replacement

Approaches to treating tricuspid valve disease are at the forefront of current clinical investigation. Utilization of an established large animal model to evaluate novel valves is required for regulatory approval prior to clinical investigation. Here we present a sheep model of surgical tricuspid valve replacement using a clinically approved surgical prosthesis. Five adult sheep underwent surgical tricuspid valve replacement (STVR) using a Medtronic Mosaic™ prosthesis and were survived for 140 days per regulatory guidance. Serial clinical pathology and echocardiography data was collected. At the study endpoint, echocardiography and cardiac catheterization was performed, followed by a comprehensive necropsy. Four animals successfully underwent STVR. Epicardial echocardiography at the time of implantation and terminal procedure confirmed preserved cardiac output and effective orifice area. Serial transthoracic echocardiography showed no sign of valvular regurgitation and comparable functional parameter throughout the postoperative study period. Intracardiac catheterization at the study endpoint confirmed absence of regurgitant flow across the device at rest and under dobutamine induced stress. Gross pathology revealed a well-seated valve with preserved functional integrity and no signs of downstream thromboembolic events. Using a relevant sheep model of STVR, this study demonstrates how detailed follow-up using echocardiography, intracardiac catheterization as well as clinical and gross pathology can yield valuable long-term in vivo data on tricuspid device safety and function.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-06-30
DOI
https://doi.org/10.1038/s41598-026-59530-7
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilization and characterization of the Medtronic Mosaic in a relevant chronic ovine model of surgical tricuspid valve replacement

Jill Schappa Faustich, John P. Carney, Walt Tollison, Ellorie Liljequist et al.
Scientific Reports
Cardiac Valve Diseases and Treatments
article

Utilization and characterization of the Medtronic Mosaic in a relevant chronic ovine model of surgical tricuspid valve replacement

Jill Schappa Faustich, John P. Carney, Walt Tollison, Ellorie Liljequist, Bailey Jacoby, Rosemary F. Kelly, Koray N. Potel, Matthew Lahti
article en

Abstract

Approaches to treating tricuspid valve disease are at the forefront of current clinical investigation. Utilization of an established large animal model to evaluate novel valves is required for regulatory approval prior to clinical investigation. Here we present a sheep model of surgical tricuspid valve replacement using a clinically approved surgical prosthesis. Five adult sheep underwent surgical tricuspid valve replacement (STVR) using a Medtronic Mosaic™ prosthesis and were survived for 140 days per regulatory guidance. Serial clinical pathology and echocardiography data was collected. At the study endpoint, echocardiography and cardiac catheterization was performed, followed by a comprehensive necropsy. Four animals successfully underwent STVR. Epicardial echocardiography at the time of implantation and terminal procedure confirmed preserved cardiac output and effective orifice area. Serial transthoracic echocardiography showed no sign of valvular regurgitation and comparable functional parameter throughout the postoperative study period. Intracardiac catheterization at the study endpoint confirmed absence of regurgitant flow across the device at rest and under dobutamine induced stress. Gross pathology revealed a well-seated valve with preserved functional integrity and no signs of downstream thromboembolic events. Using a relevant sheep model of STVR, this study demonstrates how detailed follow-up using echocardiography, intracardiac catheterization as well as clinical and gross pathology can yield valuable long-term in vivo data on tricuspid device safety and function.

Scientific Reports
University of Minnesota (US), University of Minnesota System (US)
University of Minnesota
Zero hunger
Openalex Percentile: Top 8%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.