Abstract Calibration of seismometer sensitivity in observational networks is essential to ensure measurement accuracy. One of the most accurate calibration methods is on-site comparison calibration, an approach developed over the past decade. In this approach, a calibrated seismometer is installed near the target seismometer, and their local vibration signals are compared to calculate the target sensitivity. However, changes in the reference seismometer sensitivity due to temperature dependence degrade comparison calibration accuracy. This study proposes a comparison calibration system incorporating temperature correction. The accuracy of the reference sensitivity was improved by applying correction based on temperature monitoring. Using the proposed system, STS-1 seismometers were calibrated in their operational state. The midband sensitivity around 0.5 Hz was determined with uncertainties of 0.3%–0.5%, which satisfies the requirement of the observational networks. An unidentified delay of 28 ms was also found in the seismometer or the data logger. Furthermore, the relative frequency response down to 0.02 Hz was determined, and the shift of the cutoff frequency was identified. These results will help establish an on-site comparison calibration process.

Authors

Institutions

Publication Details

Journal
Seismological Research Letters
Published
2026-06-29
DOI
https://doi.org/10.1785/0220260117
Primary Topic
Seismic Waves and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-Site Comparison Calibration of Broadband Seismometers with Temperature Correction

Hideaki Nozato, Tomofumi Shimoda, Wataru Kokuyama, A. Araya
Seismological Research Letters
Seismic Waves and Analysis
article

On-Site Comparison Calibration of Broadband Seismometers with Temperature Correction

Hideaki Nozato, Tomofumi Shimoda, Wataru Kokuyama, A. Araya
article en

Abstract

Abstract Calibration of seismometer sensitivity in observational networks is essential to ensure measurement accuracy. One of the most accurate calibration methods is on-site comparison calibration, an approach developed over the past decade. In this approach, a calibrated seismometer is installed near the target seismometer, and their local vibration signals are compared to calculate the target sensitivity. However, changes in the reference seismometer sensitivity due to temperature dependence degrade comparison calibration accuracy. This study proposes a comparison calibration system incorporating temperature correction. The accuracy of the reference sensitivity was improved by applying correction based on temperature monitoring. Using the proposed system, STS-1 seismometers were calibrated in their operational state. The midband sensitivity around 0.5 Hz was determined with uncertainties of 0.3%–0.5%, which satisfies the requirement of the observational networks. An unidentified delay of 28 ms was also found in the seismometer or the data logger. Furthermore, the relative frequency response down to 0.02 Hz was determined, and the shift of the cutoff frequency was identified. These results will help establish an on-site comparison calibration process.

Seismological Research Letters
National Institute of Advanced Industrial Science and Technology (JP), The University of Tokyo (JP)
Openalex Percentile: Top 7%
Seismic Waves and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.