Reproducibility of Splanchnic Blood Flow Measured Using Phase‐Contrast MRI

Splanchnic vessel blood flow assessment can describe physiology or pathophysiology and also has clinical relevance for patients with altered abdominal blood flow, vascular neuropathy, or atherosclerotic conditions. Reliable and practicable methods for this assessment are needed. We assessed the reproducibility of non-invasive phase-contrast MRI (PC-MRI) for measuring splanchnic blood flow and its feasibility for detecting postprandial blood flow changes. We included measurements from two groups of healthy individuals (Group A: n = 10; C: n = 10) and a group of patients with type 2 diabetes (B: n = 10) from randomized, single-blind, placebo-controlled studies, and assessed blood flow with 2D PC sequences (3 Tesla Siemens Biograph MRI and 3 Tesla Philips Achieva). Blood flow was measured in the arteria mesenterica superior, truncus coeliacus, arteria hepatica (Group A only), and vena portae hepatis over multiple days, with repeated scans each day to assess variability and reproducibility. To confirm detection of postprandial changes, nine repeated measurements were acquired during ingestion of 75-g oral glucose tolerance test compared to water ingestion. Reproducibility was assessed by coefficient of variation (CoV) and limits of agreement with the mean (LoAM) using an extended Bland-Altman analysis. Blood flow in arteria mesenterica superior, truncus coeliacus, and vena portae hepatis demonstrated low intrasubject within session CoV (7%-22%) and intrasubject between session CoV (16%-26%). Blood flow in arteria hepatica had poorer CoV for both within sessions (12%) and between sessions (32%). Glucose ingestion induced a blood flow peak increase of 88% ± 52% in arteria mesenterica superior and 68% ± 36% in vena portae hepatis, both robustly detected, while no change was observed in the arteria hepatica or truncus coeliacus. In conclusion, PC-MRI is a reproducible and feasible technique for measuring blood flow in arteria mesenterica superior, truncus coeliacus, and vena portae hepatis with the ability to detect postprandial changes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT05391581, NCT06426823, NCT06774807.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-06-29
DOI
https://doi.org/10.1002/nbm.70348
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reproducibility of Splanchnic Blood Flow Measured Using Phase‐Contrast MRI

Henrik Larsson, Sophie W Nielsen, Ulrik B. Andersen, Bryan Haddock et al.
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

Reproducibility of Splanchnic Blood Flow Measured Using Phase‐Contrast MRI

Henrik Larsson, Sophie W Nielsen, Ulrik B. Andersen, Bryan Haddock, LÆRKE S. GASBJERG, Ali Asmar, T. Larsson, Ludvig S. Langberg, Lotte Alstrup, Rasmus S. Rasmussen, Mark B. Vestergaard, Frederikke H. Østergaard
article en

Abstract

Splanchnic vessel blood flow assessment can describe physiology or pathophysiology and also has clinical relevance for patients with altered abdominal blood flow, vascular neuropathy, or atherosclerotic conditions. Reliable and practicable methods for this assessment are needed. We assessed the reproducibility of non-invasive phase-contrast MRI (PC-MRI) for measuring splanchnic blood flow and its feasibility for detecting postprandial blood flow changes. We included measurements from two groups of healthy individuals (Group A: n = 10; C: n = 10) and a group of patients with type 2 diabetes (B: n = 10) from randomized, single-blind, placebo-controlled studies, and assessed blood flow with 2D PC sequences (3 Tesla Siemens Biograph MRI and 3 Tesla Philips Achieva). Blood flow was measured in the arteria mesenterica superior, truncus coeliacus, arteria hepatica (Group A only), and vena portae hepatis over multiple days, with repeated scans each day to assess variability and reproducibility. To confirm detection of postprandial changes, nine repeated measurements were acquired during ingestion of 75-g oral glucose tolerance test compared to water ingestion. Reproducibility was assessed by coefficient of variation (CoV) and limits of agreement with the mean (LoAM) using an extended Bland-Altman analysis. Blood flow in arteria mesenterica superior, truncus coeliacus, and vena portae hepatis demonstrated low intrasubject within session CoV (7%-22%) and intrasubject between session CoV (16%-26%). Blood flow in arteria hepatica had poorer CoV for both within sessions (12%) and between sessions (32%). Glucose ingestion induced a blood flow peak increase of 88% ± 52% in arteria mesenterica superior and 68% ± 36% in vena portae hepatis, both robustly detected, while no change was observed in the arteria hepatica or truncus coeliacus. In conclusion, PC-MRI is a reproducible and feasible technique for measuring blood flow in arteria mesenterica superior, truncus coeliacus, and vena portae hepatis with the ability to detect postprandial changes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT05391581, NCT06426823, NCT06774807.

NMR in BiomedicineVol. 39(8)
University of Copenhagen (DK), Frederiksberg Hospital (DK), Glostrup Hospital (DK)
European Foundation for the Study of Diabetes, Region Hovedstaden, A.P. Møller og Hustru Chastine Mc-Kinney Møllers Fond til almene Formaal, Novo Nordisk Fonden
No poverty
Openalex Percentile: Top 7%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.