An LLM-agent-based framework for calculating nodal carbon intensity in regional power systems

Regional carbon-aware operation requires nodal carbon intensity (NCI) signals that remain valid under heterogeneous operational inputs, topology changes, and network congestion; however, existing workflows for carbon-flow tracing and marginal-emission analysis are still difficult to operationalize because data integration, model configuration, and result auditing rely heavily on manual intervention. This paper proposes a large language model (LLM)-agent-in-the-loop framework in which the language model is restricted to orchestration, while dispatch optimization, physical verification, and carbon attribution are executed by deterministic modules. The framework combines a direct-current optimal power flow (DC-OPF)-based modeling layer, a four-layer verifier with Karush-Kuhn-Tucker (KKT)-inspired diagnostics, and a unified engine that computes average carbon intensity (ACI) and marginal carbon intensity (MCI) anchored to the same verified base operating point and network model. In the PJM 5-bus benchmark prompt-bank validation, the framework achieves task-pass rates of 1.00 across structured, semi-structured, and tested anomalous prompt-bank inputs, with the main parser advantage appearing on semi-structured operational notes, while the verifier reduces unsafe acceptance from 0.429 under a V2 verifier without Layer-4 certificate diagnostics to 0.048 and raises resolved recall from 0.571 to 0.952 on injected-error artifacts. Across PJM 5-bus and IEEE 14-bus benchmark attribution cases, under congestion the bounded MCI diagnostic standard deviation reaches 283.9 kg/MWh and the bounded node-to-node MCI diagnostic spread reaches 980.0 kg/MWh, while high-renewable scenarios lower mean ACI by 24% on PJM 5-bus and 30% on IEEE 14-bus. These results demonstrate that LLM-based orchestration can improve the auditability and benchmark-level operational usability of nodal carbon accounting without replacing physics-based computation.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-06-29
DOI
https://doi.org/10.1038/s41598-026-60053-4
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An LLM-agent-based framework for calculating nodal carbon intensity in regional power systems

Rui Chen, Junpeng Zhao, Y Huang, Hui Jiang et al.
Scientific Reports
Integrated Energy Systems Optimization
article

An LLM-agent-based framework for calculating nodal carbon intensity in regional power systems

Rui Chen, Junpeng Zhao, Y Huang, Hui Jiang, Fan Zhang
article en

Abstract

Regional carbon-aware operation requires nodal carbon intensity (NCI) signals that remain valid under heterogeneous operational inputs, topology changes, and network congestion; however, existing workflows for carbon-flow tracing and marginal-emission analysis are still difficult to operationalize because data integration, model configuration, and result auditing rely heavily on manual intervention. This paper proposes a large language model (LLM)-agent-in-the-loop framework in which the language model is restricted to orchestration, while dispatch optimization, physical verification, and carbon attribution are executed by deterministic modules. The framework combines a direct-current optimal power flow (DC-OPF)-based modeling layer, a four-layer verifier with Karush-Kuhn-Tucker (KKT)-inspired diagnostics, and a unified engine that computes average carbon intensity (ACI) and marginal carbon intensity (MCI) anchored to the same verified base operating point and network model. In the PJM 5-bus benchmark prompt-bank validation, the framework achieves task-pass rates of 1.00 across structured, semi-structured, and tested anomalous prompt-bank inputs, with the main parser advantage appearing on semi-structured operational notes, while the verifier reduces unsafe acceptance from 0.429 under a V2 verifier without Layer-4 certificate diagnostics to 0.048 and raises resolved recall from 0.571 to 0.952 on injected-error artifacts. Across PJM 5-bus and IEEE 14-bus benchmark attribution cases, under congestion the bounded MCI diagnostic standard deviation reaches 283.9 kg/MWh and the bounded node-to-node MCI diagnostic spread reaches 980.0 kg/MWh, while high-renewable scenarios lower mean ACI by 24% on PJM 5-bus and 30% on IEEE 14-bus. These results demonstrate that LLM-based orchestration can improve the auditability and benchmark-level operational usability of nodal carbon accounting without replacing physics-based computation.

Scientific Reports
China Southern Power Grid (China) (CN)
China Southern Power Grid
Climate action
Openalex Percentile: Top 12%
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.