Real-world integration of an autonomous artificial intelligence system for diabetic retinopathy screening in an endocrinology outpatient clinic

AIM: To evaluate a real-world clinical integration of an autonomous artificial intelligence (AI) system (AEYE Diagnostic Screening (AEYE-DS), AEYE Health, USA) for diabetic retinopathy (DR) screening using the Topcon NW500 camera (Topcon, Japan) in an endocrinology clinic. METHODS: Adults with type 1 or type 2 diabetes without previously reported DR attending routine endocrinology follow-up were invited to participate. Non-mydriatic, macula-centred fundus photographs were acquired by a novice, non-ophthalmic operator. Images were analysed by AEYE-DS to detect more-than-mild DR (mtmDR). AI-positive results prompted physician counselling and automated referral for internal confirmatory examination. RESULTS: Definitive AEYE-DS results were obtained for 95.7% (245/256) of participants without pharmacological dilation. Seventy-six (29.6%) patients screened positive for mtmDR, of whom 34 (44.7%) completed confirmatory examination at the institution's retina clinic; externally completed follow-up was not captured. Four patients (11.8% of those evaluated) required treatment with intravitreal anti-vascular endothelial growth factor therapy or panretinal photocoagulation. Additional previously unrecognised ocular conditions were identified among several AI-positive patients. Patient satisfaction was high, with >80% reporting the screening was easy to use, time-efficient and recommendable. CONCLUSIONS: In a real-world endocrinology clinic, autonomous AI screening for DR using AEYE-DS integrated with the Topcon NW500 enabled efficient DR screening and achieved high non-mydriatic imageability. A clinically relevant proportion of patients requiring ophthalmic evaluation has been captured. Internal referral for confirmatory testing enabled assessment of downstream outcomes. The findings support scalable, point-of-care autonomous screening and a stepped-referral approach for AI-positive patients.

Authors

Institutions

Publication Details

Journal
British Journal of Ophthalmology
Published
2026-06-29
DOI
https://doi.org/10.1136/bjo-2025-328991
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-world integration of an autonomous artificial intelligence system for diabetic retinopathy screening in an endocrinology outpatient clinic

Meira Fogel-Levin, Ofri Vorobichik-Berar, Iris Moroz, Shiran Shalem et al.
British Journal of Ophthalmology
Retinal Imaging and Analysis
article

Real-world integration of an autonomous artificial intelligence system for diabetic retinopathy screening in an endocrinology outpatient clinic

Meira Fogel-Levin, Ofri Vorobichik-Berar, Iris Moroz, Shiran Shalem, Alon Harris, Naama Pelz-Sinvani, Or Gil, Gabriel Katz, Gal Yaakov Cohen, Amiram Arad, Rina Gurevich, Alice Chandra Verticchio Vercellin, Brent A Siesky, Amir Tirosh
article en

Abstract

AIM: To evaluate a real-world clinical integration of an autonomous artificial intelligence (AI) system (AEYE Diagnostic Screening (AEYE-DS), AEYE Health, USA) for diabetic retinopathy (DR) screening using the Topcon NW500 camera (Topcon, Japan) in an endocrinology clinic. METHODS: Adults with type 1 or type 2 diabetes without previously reported DR attending routine endocrinology follow-up were invited to participate. Non-mydriatic, macula-centred fundus photographs were acquired by a novice, non-ophthalmic operator. Images were analysed by AEYE-DS to detect more-than-mild DR (mtmDR). AI-positive results prompted physician counselling and automated referral for internal confirmatory examination. RESULTS: Definitive AEYE-DS results were obtained for 95.7% (245/256) of participants without pharmacological dilation. Seventy-six (29.6%) patients screened positive for mtmDR, of whom 34 (44.7%) completed confirmatory examination at the institution's retina clinic; externally completed follow-up was not captured. Four patients (11.8% of those evaluated) required treatment with intravitreal anti-vascular endothelial growth factor therapy or panretinal photocoagulation. Additional previously unrecognised ocular conditions were identified among several AI-positive patients. Patient satisfaction was high, with >80% reporting the screening was easy to use, time-efficient and recommendable. CONCLUSIONS: In a real-world endocrinology clinic, autonomous AI screening for DR using AEYE-DS integrated with the Topcon NW500 enabled efficient DR screening and achieved high non-mydriatic imageability. A clinically relevant proportion of patients requiring ophthalmic evaluation has been captured. Internal referral for confirmatory testing enabled assessment of downstream outcomes. The findings support scalable, point-of-care autonomous screening and a stepped-referral approach for AI-positive patients.

British Journal of Ophthalmology
Sheba Medical Center (IL), Icahn School of Medicine at Mount Sinai (US)
Openalex Percentile: Top 7%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.