Experimental investigation on prestressed concrete beams with localized strand damage: Tilt-based deflection mapping and damage indicators

This study investigates the structural response of prestressed concrete beams with localized strand damage under both serviceability and ultimate loading conditions. Seven simply supported beams, with a clear span of L = 7.0 m, were cast as scaled bridge girders representing different damage scenarios. Inspection windows were created at L /2, L /3, and L /4 to simulate corrosion-induced defects by selectively severing prestressing strands in a controlled manner, thereby reducing the effective prestressing steel area. The beams were tested under combined dead load and increasing midspan live load, applied through loading-unloading cycles from service levels up to failure. A dense network of MEMS tiltmeters was used to measure spanwise rotations, which were converted into deflection profiles using a straightforward slope-integration procedure that preserved support compatibility and was cross-validated against independent laser targets and LVDTs. Based on the reconstructed deflected shapes under incremental quasi-static cycles at serviceability load levels, two complementary sets of damage indicators were defined. The first set, DI₁ (loading), includes the absolute peak deflection during the load plateau (DI 1- u ) and its position (DI 1- x ). The second set, DI₂ (residual), includes the peak residual deflection after unloading (DI 2- u ) and its location (DI 2- x ). The u components reflect damage severity, while the x components provide damage localization. These indicators consistently identified the damaged regions and scaled with the number and position of severed strands, in agreement with force–displacement responses, moment–curvature relationships from sectional analysis and observed failure modes. The results demonstrate that rapid static testing combining tilt-based deflection mapping and local crack-opening measurements provides a practical and reliable approach for detecting, ranking, and localizing tendon damage in prestressed concrete girders.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2026-06-30
DOI
https://doi.org/10.1016/j.engstruct.2026.123270
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation on prestressed concrete beams with localized strand damage: Tilt-based deflection mapping and damage indicators

Dario De Domenico, Antonino Recupero, Amir Shamsaddinlou
Engineering Structures
Structural Behavior of Reinforced Concrete
article

Experimental investigation on prestressed concrete beams with localized strand damage: Tilt-based deflection mapping and damage indicators

Dario De Domenico, Antonino Recupero, Amir Shamsaddinlou
article en

Abstract

This study investigates the structural response of prestressed concrete beams with localized strand damage under both serviceability and ultimate loading conditions. Seven simply supported beams, with a clear span of L = 7.0 m, were cast as scaled bridge girders representing different damage scenarios. Inspection windows were created at L /2, L /3, and L /4 to simulate corrosion-induced defects by selectively severing prestressing strands in a controlled manner, thereby reducing the effective prestressing steel area. The beams were tested under combined dead load and increasing midspan live load, applied through loading-unloading cycles from service levels up to failure. A dense network of MEMS tiltmeters was used to measure spanwise rotations, which were converted into deflection profiles using a straightforward slope-integration procedure that preserved support compatibility and was cross-validated against independent laser targets and LVDTs. Based on the reconstructed deflected shapes under incremental quasi-static cycles at serviceability load levels, two complementary sets of damage indicators were defined. The first set, DI₁ (loading), includes the absolute peak deflection during the load plateau (DI 1- u ) and its position (DI 1- x ). The second set, DI₂ (residual), includes the peak residual deflection after unloading (DI 2- u ) and its location (DI 2- x ). The u components reflect damage severity, while the x components provide damage localization. These indicators consistently identified the damaged regions and scaled with the number and position of severed strands, in agreement with force–displacement responses, moment–curvature relationships from sectional analysis and observed failure modes. The results demonstrate that rapid static testing combining tilt-based deflection mapping and local crack-opening measurements provides a practical and reliable approach for detecting, ranking, and localizing tendon damage in prestressed concrete girders.

Engineering StructuresVol. 365
University of Messina (IT)
Sustainable cities and communities
Openalex Percentile: Top 12%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.