3D virtual histopathology of human breast tissues using an X-ray grating interferometry micro CT system

BACKGROUND: Breast cancer remains the most prevalent malignancy among women worldwide. When suspicious lesions are detected, standard clinical workflows rely on histopathological evaluation of excised tissue (biopsy) and the choice of preoperative systemic therapies or primary surgical excision. This study explores the potential of X-ray grating-interferometry (GI)-based micro-computed tomography (μCT) as a complementary virtual tool to the gold-standard conventional histopathology Methods: Small (up to 2 cm) residual samples from 20 formalin-fixed mastectomy specimens (from 19 patients) underwent imaging using GI-based μCT and were subsequently processed for routine histology. Diagnostic concordance between gold-standard histological sections and μCT images was established with input from an expert pathologist and an expert radiologist Results: GI-based μCT enabled differentiation of neoplastic and benign findings from surrounding tissue based on morphology and gray-value contrast. While μCT lacks the cellular resolution of histology, its 3D volumetric data provided valuable spatial context for small structures. Imaging a 2 cm specimen required approximately 13.4 h, with negligible degradation in diagnostic image quality when the acquisition time was reduced to 4.4 h Conclusions: GI-based μCT demonstrates strong potential as an adjunct to gold-standard histopathology, providing high-quality soft-tissue contrast comparable to conventional μCT and aiding in the identification of regions of interest for further tissue-based analysis. The possible clinical utility of GI-based μCT diagnostics needs further clinical evaluation, also on smaller samples.

Authors

Institutions

Publication Details

Journal
Experimental and Molecular Pathology
Published
2026-06-30
DOI
https://doi.org/10.1016/j.yexmp.2026.105060
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D virtual histopathology of human breast tissues using an X-ray grating interferometry micro CT system

Zsuzsanna Varga, Jonas Kroschke, Konstantins Jefimovs, Thomas Frauenfelder et al.
Experimental and Molecular Pathology
Advanced X-ray Imaging Techniques
article

3D virtual histopathology of human breast tissues using an X-ray grating interferometry micro CT system

Zsuzsanna Varga, Jonas Kroschke, Konstantins Jefimovs, Thomas Frauenfelder, D. Josell, Stefanie Kaser, Marco Stampanoni, Alexandre Pereira, Lucia Romano
article en

Abstract

BACKGROUND: Breast cancer remains the most prevalent malignancy among women worldwide. When suspicious lesions are detected, standard clinical workflows rely on histopathological evaluation of excised tissue (biopsy) and the choice of preoperative systemic therapies or primary surgical excision. This study explores the potential of X-ray grating-interferometry (GI)-based micro-computed tomography (μCT) as a complementary virtual tool to the gold-standard conventional histopathology Methods: Small (up to 2 cm) residual samples from 20 formalin-fixed mastectomy specimens (from 19 patients) underwent imaging using GI-based μCT and were subsequently processed for routine histology. Diagnostic concordance between gold-standard histological sections and μCT images was established with input from an expert pathologist and an expert radiologist Results: GI-based μCT enabled differentiation of neoplastic and benign findings from surrounding tissue based on morphology and gray-value contrast. While μCT lacks the cellular resolution of histology, its 3D volumetric data provided valuable spatial context for small structures. Imaging a 2 cm specimen required approximately 13.4 h, with negligible degradation in diagnostic image quality when the acquisition time was reduced to 4.4 h Conclusions: GI-based μCT demonstrates strong potential as an adjunct to gold-standard histopathology, providing high-quality soft-tissue contrast comparable to conventional μCT and aiding in the identification of regions of interest for further tissue-based analysis. The possible clinical utility of GI-based μCT diagnostics needs further clinical evaluation, also on smaller samples.

Experimental and Molecular PathologyVol. 147
National Institute of Standards and Technology (US), Paul Scherrer Institute (CH), Institute for Biomedical Engineering (CH), University Hospital of Zurich (CH)
Promedica Stiftung
Zero hunger
Openalex Percentile: Top 9%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.