Structural Performance and Boundary Effects of Dry-Jointed Sliding Masonry Infill Walls with Openings Under Sequential In-Plane and Out-of-Plane Loading

Conventional masonry infill walls can significantly alter the seismic response of framed buildings and often produce damage patterns incompatible with resilience-based seismic design. Dry-jointed sliding masonry wall systems have therefore emerged as deformation-tolerant alternatives that accommodate drift through controlled interface motion rather than damage accumulation. This study investigates the sequential in-plane (IP) and out-of-plane (OOP) behavior of such systems considering wall thickness, openings, and boundary detailing. Six full-scale specimens were tested, including thick- and thin-wall reference specimens, thick-wall specimens with window openings, and thin-wall specimens with door openings. IP performance was evaluated using global hysteretic and energy-based response parameters, whereas OOP behavior was assessed through load–displacement response, an equivalent acceleration index, and selected image-based displacement fields. The results show that IP drift was mainly accommodated through distributed sliding along horizontal interfaces and local block rotation, without diagonal compression strut formation or brittle cracking, even at drift ratios up to approximately 3.5%. Wall thickness improved IP strength, stiffness, shear resistance, and cumulative energy dissipation, while openings mainly affected deformation compatibility and load-transfer continuity. Under OOP loading, wall thickness and boundary continuity increased stiffness and capacity while enabling resistance mobilization at smaller displacement levels. As inertia-based comparison indicators, boundary-enhanced thick- and thin-wall specimens reached equivalent acceleration capacities of 3.41 g and 1.64 g, respectively. Overall, the system reduced IP damage accumulation, but adequate OOP stability requires appropriate wall thickness, unit geometry, and boundary detailing.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-06-28
DOI
https://doi.org/10.3390/buildings16132580
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural Performance and Boundary Effects of Dry-Jointed Sliding Masonry Infill Walls with Openings Under Sequential In-Plane and Out-of-Plane Loading

Okan Önal, Sadık Can Girgin, İbrahim Serkan Mısır, Cagri Cetik et al.
Buildings
Masonry and Concrete Structural Analysis
article

Structural Performance and Boundary Effects of Dry-Jointed Sliding Masonry Infill Walls with Openings Under Sequential In-Plane and Out-of-Plane Loading

Okan Önal, Sadık Can Girgin, İbrahim Serkan Mısır, Cagri Cetik, Ali Cihan Demir
article en

Abstract

Conventional masonry infill walls can significantly alter the seismic response of framed buildings and often produce damage patterns incompatible with resilience-based seismic design. Dry-jointed sliding masonry wall systems have therefore emerged as deformation-tolerant alternatives that accommodate drift through controlled interface motion rather than damage accumulation. This study investigates the sequential in-plane (IP) and out-of-plane (OOP) behavior of such systems considering wall thickness, openings, and boundary detailing. Six full-scale specimens were tested, including thick- and thin-wall reference specimens, thick-wall specimens with window openings, and thin-wall specimens with door openings. IP performance was evaluated using global hysteretic and energy-based response parameters, whereas OOP behavior was assessed through load–displacement response, an equivalent acceleration index, and selected image-based displacement fields. The results show that IP drift was mainly accommodated through distributed sliding along horizontal interfaces and local block rotation, without diagonal compression strut formation or brittle cracking, even at drift ratios up to approximately 3.5%. Wall thickness improved IP strength, stiffness, shear resistance, and cumulative energy dissipation, while openings mainly affected deformation compatibility and load-transfer continuity. Under OOP loading, wall thickness and boundary continuity increased stiffness and capacity while enabling resistance mobilization at smaller displacement levels. As inertia-based comparison indicators, boundary-enhanced thick- and thin-wall specimens reached equivalent acceleration capacities of 3.41 g and 1.64 g, respectively. Overall, the system reduced IP damage accumulation, but adequate OOP stability requires appropriate wall thickness, unit geometry, and boundary detailing.

BuildingsVol. 16(13)
Dokuz Eylül University (TR)
Sustainable cities and communities
Openalex Percentile: Top 11%
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.