The Effect of Virtual Reality Glasses Application During Urodynamics on Procedural Pain, Anxiety, and Hemodynamic Parameters: A Randomized Controlled Trial

Purpose: To evaluate the effectiveness of virtual reality glasses (VRG) intervention during urodynamic testing (UT) on procedural pain (PP), anxiety levels, and hemodynamic parameters.Methods: This prospective, randomized controlled trial enrolled 84 patients undergoing UT, randomized 1:1 to VRG (n=42) or control group (n=42). The VRG group viewed immersive 3-dimensional nature videos via VRG throughout the procedure, while controls received routine care. Primary outcomes included PP (visual analogue scale) and anxiety levels (State Anxiety Inventory) assessed at baseline (pre-UT1), immediately postprocedure (post-UT2), and 15 minutes postprocedure (post-UT3). Secondary outcomes comprised hemodynamic parameters (systolic blood pressure [SBP], diastolic blood pressure [DBP], heart rate [HR], respiratory rate [RR], oxygen saturation [SpO₂]) measured at identical timepoints.Results: Groups demonstrated comparable baseline characteristics and PP scores (VRG: 2.52±2.76 vs. control: 3.07±2.99, P=0.386). While baseline anxiety levels were similar between groups, the VRG group exhibited significantly lower postprocedural anxiety scores (post-UT2: 34.64±4.98 vs. 39.21±8.11, P=0.003; post-UT3: 34.45±4.68 vs. 39.45±8.27, P=0.001). Hemodynamically, the VRG group demonstrated significantly reduced DBP at post-UT3 (73.4±9.7 mmHg vs. 78.7±12.0 mmHg, P=0.028) and lower RRs at both postprocedural timepoints (P<0.001 and P=0.015, respectively). No significant between-group differences were observed for SBP, HR, or SpO₂.Conclusions: VRG intervention during UT effectively reduced postprocedural anxiety and demonstrated beneficial effects on RR and DBP, without significantly impacting PP. These findings support the use of VRG by nurses as a safe, nonpharmacological adjunct for enhancing patient comfort during invasive urological procedures.

Authors

Institutions

Publication Details

Journal
International Neurourology Journal
Published
2026-06-29
DOI
https://doi.org/10.5213/inj.2550260.130
Primary Topic
Urinary Bladder and Prostate Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Virtual Reality Glasses Application During Urodynamics on Procedural Pain, Anxiety, and Hemodynamic Parameters: A Randomized Controlled Trial

Murat Bozlu, Gamze Bozkul, Elife Kettaş Dölek, Gülay Altun Uğraş
International Neurourology Journal
Urinary Bladder and Prostate Research
article

The Effect of Virtual Reality Glasses Application During Urodynamics on Procedural Pain, Anxiety, and Hemodynamic Parameters: A Randomized Controlled Trial

Murat Bozlu, Gamze Bozkul, Elife Kettaş Dölek, Gülay Altun Uğraş
article en

Abstract

Purpose: To evaluate the effectiveness of virtual reality glasses (VRG) intervention during urodynamic testing (UT) on procedural pain (PP), anxiety levels, and hemodynamic parameters.Methods: This prospective, randomized controlled trial enrolled 84 patients undergoing UT, randomized 1:1 to VRG (n=42) or control group (n=42). The VRG group viewed immersive 3-dimensional nature videos via VRG throughout the procedure, while controls received routine care. Primary outcomes included PP (visual analogue scale) and anxiety levels (State Anxiety Inventory) assessed at baseline (pre-UT1), immediately postprocedure (post-UT2), and 15 minutes postprocedure (post-UT3). Secondary outcomes comprised hemodynamic parameters (systolic blood pressure [SBP], diastolic blood pressure [DBP], heart rate [HR], respiratory rate [RR], oxygen saturation [SpO₂]) measured at identical timepoints.Results: Groups demonstrated comparable baseline characteristics and PP scores (VRG: 2.52±2.76 vs. control: 3.07±2.99, P=0.386). While baseline anxiety levels were similar between groups, the VRG group exhibited significantly lower postprocedural anxiety scores (post-UT2: 34.64±4.98 vs. 39.21±8.11, P=0.003; post-UT3: 34.45±4.68 vs. 39.45±8.27, P=0.001). Hemodynamically, the VRG group demonstrated significantly reduced DBP at post-UT3 (73.4±9.7 mmHg vs. 78.7±12.0 mmHg, P=0.028) and lower RRs at both postprocedural timepoints (P<0.001 and P=0.015, respectively). No significant between-group differences were observed for SBP, HR, or SpO₂.Conclusions: VRG intervention during UT effectively reduced postprocedural anxiety and demonstrated beneficial effects on RR and DBP, without significantly impacting PP. These findings support the use of VRG by nurses as a safe, nonpharmacological adjunct for enhancing patient comfort during invasive urological procedures.

International Neurourology JournalVol. 30(2)
Tarsus University (TR), Mersin Üniversitesi (TR)
Good health and well-being
Openalex Percentile: Top 7%
Urinary Bladder and Prostate Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.