Biomechanical Evaluation of a Hybrid Fixation Strategy: Enhancing Intramedullary Nail Stability With a Trochanteric Stabilization Plate in Unstable Intertrochanteric Fractures With Lateral Wall Collapse

Introduction Unstable reverse oblique intertrochanteric fractures with lateral wall collapse present a unique fixation challenge due to the absence of a lateral buttress. When treated with standard implants, this structural deficit frequently leads to construct failure through varus malunion and medialization of the femoral shaft. A device developed to provide rigidity for the maintenance of fracture reduction would bridge this gap. This study evaluates the biomechanical performance of a hybrid fixation strategy utilizing a Trochanteric Stabilization Plate for Nails (TSPN) in combination with an intramedullary nail (IMN) for such fractures using finite element analysis (FEA) and mechanical testing. Methods The study compared standard IMN fixation to a hybrid IMN-TSPN construct by simulating fracture scenarios in a validated femur model and performing mechanical tests on composite bone specimens (total n = 10; n = 5 per group). Finite element analysis quantified computational deformation, stress distribution, and elastic strain, while experimental physical tests measured construct stiffness and failure load under static axial compression. Statistical significance for experimental outcomes was evaluated using the non-parametric Mann-Whitney U test with a Bonferroni correction. Results The IMN-TSPN hybrid construct demonstrated a significant 1.85-fold increase in experimental structural rigidity (p = 0.008) and higher physical failure thresholds compared to IMN alone. Computationally, TSPN augmentation substantially reduced maximum fracture-gap displacement, peak elastic strain, and peak von Mises stress. The TSPN effectively redistributed loading and minimized total construct deformation. Conclusion In a composite bone model under static axial loading, augmenting an IMN with a TSPN significantly increased construct stiffness and reduced deformation compared to IMN alone. These findings suggest a biomechanical advantage that warrants further testing in clinically representative, dynamic models.

Authors

Publication Details

Journal
Cureus
Published
2026-06-27
DOI
https://doi.org/10.7759/cureus.111635
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical Evaluation of a Hybrid Fixation Strategy: Enhancing Intramedullary Nail Stability With a Trochanteric Stabilization Plate in Unstable Intertrochanteric Fractures With Lateral Wall Collapse

Nikhilesh Das, Sudipto Mukherjee, Nithin Shajeendran, Nikunj Patel et al.
Cureus
Hip and Femur Fractures
article

Biomechanical Evaluation of a Hybrid Fixation Strategy: Enhancing Intramedullary Nail Stability With a Trochanteric Stabilization Plate in Unstable Intertrochanteric Fractures With Lateral Wall Collapse

Nikhilesh Das, Sudipto Mukherjee, Nithin Shajeendran, Nikunj Patel, Pranav Thaker, Swathy G Nurani
article en

Abstract

Introduction Unstable reverse oblique intertrochanteric fractures with lateral wall collapse present a unique fixation challenge due to the absence of a lateral buttress. When treated with standard implants, this structural deficit frequently leads to construct failure through varus malunion and medialization of the femoral shaft. A device developed to provide rigidity for the maintenance of fracture reduction would bridge this gap. This study evaluates the biomechanical performance of a hybrid fixation strategy utilizing a Trochanteric Stabilization Plate for Nails (TSPN) in combination with an intramedullary nail (IMN) for such fractures using finite element analysis (FEA) and mechanical testing. Methods The study compared standard IMN fixation to a hybrid IMN-TSPN construct by simulating fracture scenarios in a validated femur model and performing mechanical tests on composite bone specimens (total n = 10; n = 5 per group). Finite element analysis quantified computational deformation, stress distribution, and elastic strain, while experimental physical tests measured construct stiffness and failure load under static axial compression. Statistical significance for experimental outcomes was evaluated using the non-parametric Mann-Whitney U test with a Bonferroni correction. Results The IMN-TSPN hybrid construct demonstrated a significant 1.85-fold increase in experimental structural rigidity (p = 0.008) and higher physical failure thresholds compared to IMN alone. Computationally, TSPN augmentation substantially reduced maximum fracture-gap displacement, peak elastic strain, and peak von Mises stress. The TSPN effectively redistributed loading and minimized total construct deformation. Conclusion In a composite bone model under static axial loading, augmenting an IMN with a TSPN significantly increased construct stiffness and reduced deformation compared to IMN alone. These findings suggest a biomechanical advantage that warrants further testing in clinically representative, dynamic models.

Cureus
Sustainable cities and communities
Openalex Percentile: Top 5%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.