Vibration mitigation for wind turbines using electromagnetic shunt damper with negative impedance converter

Recognizing the electromagnetic shunt damper (EMSD) as a vibration control device that enables versatile mechanical behavior through appropriate shunt-circuit configurations, this study investigates its application to a 10 MW steel-concrete hybrid wind turbine (HWT). An enhanced EMSD, namely, N-EMSD, composed of an electromagnetic damper (EMD), a negative impedance converter (NIC), and an RLC circuit, is employed to replace the damping unit of a conventional tuned mass damper (TMD) and to construct the analyzed mass-EMSD. First, the merits of introducing NIC for N-EMSD and the detailed mechanism of N-EMSD were presented. The NIC renders theoretically feasible the realization of versatile mechanical behaviors of the EMSD. Circuit tests for the NIC were conducted. Subsequently, a Simulink-OpenFAST coupled model is established, covering the excitation, HWT structural dynamics, and the N-EMSD with electromechanical dynamics. The control performance of the mass-EMSD is evaluated using the coupled model in the normal operation mode. The control device is applied in the side-to-side direction of the HWT. The mass-EMSD achieves promising control effects, with reduction ratios of tens of percent in the standard deviation of tower-top side-to-side displacement and the associated root-mean-square acceleration, slightly outperforming those of the TMD. In addition, the power generation and pitch control effects are analyzed in the modeling; the introduction of control devices has limited effects on these aspects. These results demonstrate that the proposed mass-EMSD is an effective control device for HWT, shedding light on the development of electromagnetic-oriented vibration control strategies for WTs.

Authors

Institutions

Publication Details

Journal
Journal of Vibration and Control
Published
2026-06-28
DOI
https://doi.org/10.1177/10775463261463707
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Vibration mitigation for wind turbines using electromagnetic shunt damper with negative impedance converter

Xudong Wang, Kaoshan Dai, 蔡钦林, Xiang Shi et al.
Journal of Vibration and Control
Vibration Control and Rheological Fluids
article

Vibration mitigation for wind turbines using electromagnetic shunt damper with negative impedance converter

Xudong Wang, Kaoshan Dai, 蔡钦林, Xiang Shi, Ji Tang, Yuxiao LUO
article en

Abstract

Recognizing the electromagnetic shunt damper (EMSD) as a vibration control device that enables versatile mechanical behavior through appropriate shunt-circuit configurations, this study investigates its application to a 10 MW steel-concrete hybrid wind turbine (HWT). An enhanced EMSD, namely, N-EMSD, composed of an electromagnetic damper (EMD), a negative impedance converter (NIC), and an RLC circuit, is employed to replace the damping unit of a conventional tuned mass damper (TMD) and to construct the analyzed mass-EMSD. First, the merits of introducing NIC for N-EMSD and the detailed mechanism of N-EMSD were presented. The NIC renders theoretically feasible the realization of versatile mechanical behaviors of the EMSD. Circuit tests for the NIC were conducted. Subsequently, a Simulink-OpenFAST coupled model is established, covering the excitation, HWT structural dynamics, and the N-EMSD with electromechanical dynamics. The control performance of the mass-EMSD is evaluated using the coupled model in the normal operation mode. The control device is applied in the side-to-side direction of the HWT. The mass-EMSD achieves promising control effects, with reduction ratios of tens of percent in the standard deviation of tower-top side-to-side displacement and the associated root-mean-square acceleration, slightly outperforming those of the TMD. In addition, the power generation and pitch control effects are analyzed in the modeling; the introduction of control devices has limited effects on these aspects. These results demonstrate that the proposed mass-EMSD is an effective control device for HWT, shedding light on the development of electromagnetic-oriented vibration control strategies for WTs.

Journal of Vibration and Control
Sichuan University (CN), China University of Petroleum, East China (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China, Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 11%
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.