Adjunctive Electrolytic Implant Surface Decontamination in the Reconstructive Surgical Treatment of Peri‐Implantitis—A Randomized Clinical Trial

OBJECTIVES: The aim of this study was to evaluate the adjunctive effect of electrolytic cleaning in the surgical treatment of peri-implantitis. MATERIALS AND METHODS: A total of 40 patients (44 implants) with peri-implantitis-associated intra-bony defects were included in this single-center randomized controlled trial. Surgical decontamination of implant surfaces was initiated by use of a rotating titanium brush. Following random allocation, adjunctive electrolytic cleaning was performed in the test group. Xenogeneic bone substitute and a resorbable collagen membrane were then used in both groups. Clinical parameters including probing pocket depth (PPD), bleeding/suppuration on probing, buccal mucosal recession (REC), and keratinized mucosa were assessed at 6 and 12 months. Radiographic marginal bone levels (MBL) and patient-reported outcomes (PROs) were evaluated at 12 months. The primary outcome was a composite measure including implant survival, complete absence of BoP/SoP, PPD ≤ 5 mm and REC ≤ 1 mm at 12 months. RESULTS: At 12 months, no implants were lost. The composite outcome was complete at 27.3% of control and 40.0% of test implants (p = 0.41). Mean PPD reductions were 4.5 ± 2.6 mm (control) and 3.8 ± 2.3 mm (test), while MBL gains were 1.9 ± 2.4 mm and 2.1 ± 2.0 mm, respectively. No significant intergroup differences were observed for any clinical, radiographic or PROs. Post-surgical complications occurred in the test group. CONCLUSIONS: Clinical, radiographic and patient-reported outcomes of surgical therapy of peri-implantitis were favorable at 12 months. The adjunctive use of electrolytic cleaning provided no added benefit over the use of a rotating titanium brush alone. TRIAL REGISTRATION: ISRCTN17197337 (ISRCTN).

Authors

Institutions

Publication Details

Journal
Clinical Oral Implants Research
Published
2026-06-28
DOI
https://doi.org/10.1111/clr.70152
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adjunctive Electrolytic Implant Surface Decontamination in the Reconstructive Surgical Treatment of Peri‐Implantitis—A Randomized Clinical Trial

Erik Regidor, Jan B Derks, Alberto Ortiz‐Vigón, Kostas Bougas et al.
Clinical Oral Implants Research
Dental Implant Techniques and Outcomes
article

Adjunctive Electrolytic Implant Surface Decontamination in the Reconstructive Surgical Treatment of Peri‐Implantitis—A Randomized Clinical Trial

Erik Regidor, Jan B Derks, Alberto Ortiz‐Vigón, Kostas Bougas, Jessica Berglundh
article en

Abstract

OBJECTIVES: The aim of this study was to evaluate the adjunctive effect of electrolytic cleaning in the surgical treatment of peri-implantitis. MATERIALS AND METHODS: A total of 40 patients (44 implants) with peri-implantitis-associated intra-bony defects were included in this single-center randomized controlled trial. Surgical decontamination of implant surfaces was initiated by use of a rotating titanium brush. Following random allocation, adjunctive electrolytic cleaning was performed in the test group. Xenogeneic bone substitute and a resorbable collagen membrane were then used in both groups. Clinical parameters including probing pocket depth (PPD), bleeding/suppuration on probing, buccal mucosal recession (REC), and keratinized mucosa were assessed at 6 and 12 months. Radiographic marginal bone levels (MBL) and patient-reported outcomes (PROs) were evaluated at 12 months. The primary outcome was a composite measure including implant survival, complete absence of BoP/SoP, PPD ≤ 5 mm and REC ≤ 1 mm at 12 months. RESULTS: At 12 months, no implants were lost. The composite outcome was complete at 27.3% of control and 40.0% of test implants (p = 0.41). Mean PPD reductions were 4.5 ± 2.6 mm (control) and 3.8 ± 2.3 mm (test), while MBL gains were 1.9 ± 2.4 mm and 2.1 ± 2.0 mm, respectively. No significant intergroup differences were observed for any clinical, radiographic or PROs. Post-surgical complications occurred in the test group. CONCLUSIONS: Clinical, radiographic and patient-reported outcomes of surgical therapy of peri-implantitis were favorable at 12 months. The adjunctive use of electrolytic cleaning provided no added benefit over the use of a rotating titanium brush alone. TRIAL REGISTRATION: ISRCTN17197337 (ISRCTN).

Clinical Oral Implants Research
Universidad Complutense de Madrid (ES), University of Gothenburg (SE)
Openalex Percentile: Top 6%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.