Axial length correction in retinal thickness measurements in diabetic retinopathy

Abstract Purpose To use the RS-1 Glauvas (NIDEK) system to evaluate the effect of axial length (AL) correction on retinal thickness (RT) with optical coherence tomography (OCT). Study design Observational, cross-sectional study. Methods Between November 2023 and April 2024, 165 eyes from patients with diabetes underwent OCT imaging. RT was measured with and without AL-based magnification correction with the Early Treatment Diabetic Retinopathy Study (ETDRS) grid, which comprises three concentric circles (diameters; 1, 3, and 6 mm), with the inner and outer rings divided into superior, temporal, nasal, and inferior sectors. Measurements were calculated using two settings: a fixed AL of 24 mm (uncorrected) and the individually measured AL for each eye (corrected). The difference between uncorrected and corrected RT measurements was analyzed using Bland–Altman analysis. Linear regression analysis was performed to assess the association between AL and the measurement difference. Results The mean AL was 23.9 ± 1.2 mm. Bland–Altman analysis for central subfield thickness (CST) showed a small mean difference between corrected and uncorrected measurements (bias −0.34 µm; 95% limits of agreement −6.32 to 5.63 µm). Linear regression demonstrated a significant positive association between AL and the difference in CST measurements (R 2 = 0.70, p < 0.0001), indicating that uncorrected measurements tended to underestimate and overestimate RT in eyes with shorter and longer AL, respectively. Conclusion AL differences affect the effective OCT scan area and may influence RT measurements. Applying AL correction minimizes measurement bias caused by transverse magnification and improves the accuracy of RT assessment.

Authors

Institutions

Publication Details

Journal
Japanese Journal of Ophthalmology
Published
2026-06-29
DOI
https://doi.org/10.1007/s10384-026-01393-6
Primary Topic
Retinal Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Axial length correction in retinal thickness measurements in diabetic retinopathy

Shinji Kakihara, Shun Ito, Ken Hoshiyama, Takao Hirano et al.
Japanese Journal of Ophthalmology
Retinal Diseases and Treatments
article

Axial length correction in retinal thickness measurements in diabetic retinopathy

Shinji Kakihara, Shun Ito, Ken Hoshiyama, Takao Hirano, Yoshiaki Chiku, Toshinori Murata, Ryuji Tomihara, Shuji Mukawa, Hitomi Fujihara, Shingo Kajiwara, Erika Sekiya
article en

Abstract

Abstract Purpose To use the RS-1 Glauvas (NIDEK) system to evaluate the effect of axial length (AL) correction on retinal thickness (RT) with optical coherence tomography (OCT). Study design Observational, cross-sectional study. Methods Between November 2023 and April 2024, 165 eyes from patients with diabetes underwent OCT imaging. RT was measured with and without AL-based magnification correction with the Early Treatment Diabetic Retinopathy Study (ETDRS) grid, which comprises three concentric circles (diameters; 1, 3, and 6 mm), with the inner and outer rings divided into superior, temporal, nasal, and inferior sectors. Measurements were calculated using two settings: a fixed AL of 24 mm (uncorrected) and the individually measured AL for each eye (corrected). The difference between uncorrected and corrected RT measurements was analyzed using Bland–Altman analysis. Linear regression analysis was performed to assess the association between AL and the measurement difference. Results The mean AL was 23.9 ± 1.2 mm. Bland–Altman analysis for central subfield thickness (CST) showed a small mean difference between corrected and uncorrected measurements (bias −0.34 µm; 95% limits of agreement −6.32 to 5.63 µm). Linear regression demonstrated a significant positive association between AL and the difference in CST measurements (R 2 = 0.70, p < 0.0001), indicating that uncorrected measurements tended to underestimate and overestimate RT in eyes with shorter and longer AL, respectively. Conclusion AL differences affect the effective OCT scan area and may influence RT measurements. Applying AL correction minimizes measurement bias caused by transverse magnification and improves the accuracy of RT assessment.

Japanese Journal of Ophthalmology
Shinshu University (JP), Shinshu University Hospital (JP)
Shinshu University
Good health and well-being
Openalex Percentile: Top 7%
Retinal Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.