Simultaneous measurement of nitric oxide concentration and temperature using overlapping absorption signals in direct absorption spectroscopy at 5181.2 nm

Simultaneous measurement of temperature and nitric oxide (NO) concentration is essential for reliable combustion diagnostics. In this study, a single quantum cascade laser (QCL) scanning the range of 1929.4–1931.3 cm⁻ 1 was used to concurrently retrieve temperature and NO concentration, specifically addressing the spectral overlap of NO and H 2 O signals. To minimize baseline fitting errors inherent in these overlapping features, we developed an analysis algorithm incorporating a Householder reflection–based orthogonalization process. The proposed method determines temperature and NO concentration by comparing baseline-corrected measured spectra with reconstructed virtual spectra. We validated the retrieved temperature against thermocouple measurements and compared H 2 O concentration results with 1.3 µm TDLAS data. Additionally, NO measurements were evaluated against an electrochemical sensor. Experimental results demonstrated consistent agreement across the tested range (603–653 K), confirming that this single-laser approach reduces system complexity while providing enhanced diagnostic reliability in high-humidity environments.

Authors

Institutions

Publication Details

Journal
Optics & Laser Technology
Published
2026-06-28
DOI
https://doi.org/10.1016/j.optlastec.2026.115778
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous measurement of nitric oxide concentration and temperature using overlapping absorption signals in direct absorption spectroscopy at 5181.2 nm

D H Kim, Aran Song, Jiyeon Park, Jungho Hwang et al.
Optics & Laser Technology
Spectroscopy and Laser Applications
article

Simultaneous measurement of nitric oxide concentration and temperature using overlapping absorption signals in direct absorption spectroscopy at 5181.2 nm

D H Kim, Aran Song, Jiyeon Park, Jungho Hwang, Changyeop Lee, Miyeon Yoo
article en

Abstract

Simultaneous measurement of temperature and nitric oxide (NO) concentration is essential for reliable combustion diagnostics. In this study, a single quantum cascade laser (QCL) scanning the range of 1929.4–1931.3 cm⁻ 1 was used to concurrently retrieve temperature and NO concentration, specifically addressing the spectral overlap of NO and H 2 O signals. To minimize baseline fitting errors inherent in these overlapping features, we developed an analysis algorithm incorporating a Householder reflection–based orthogonalization process. The proposed method determines temperature and NO concentration by comparing baseline-corrected measured spectra with reconstructed virtual spectra. We validated the retrieved temperature against thermocouple measurements and compared H 2 O concentration results with 1.3 µm TDLAS data. Additionally, NO measurements were evaluated against an electrochemical sensor. Experimental results demonstrated consistent agreement across the tested range (603–653 K), confirming that this single-laser approach reduces system complexity while providing enhanced diagnostic reliability in high-humidity environments.

Optics & Laser TechnologyVol. 203
Yonsei University (KR), Sungkyunkwan University (KR), Korea Institute of Industrial Technology (KR)
Korea Evaluation Institute of Industrial Technology
Affordable and clean energy
Openalex Percentile: Top 13%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.