Dehydroepiandrosterone (DHEA) and Dehydroepiandrosterone Sulfate (DHEA-S) in Broiler Plasma: Analytical Validation of Immunoassays and Comparative Overview Across Avian Species

This study validated immunoassays for measuring circulating DHEA and DHEA-S in broiler plasma and compared the two biomarkers. A commercially available RIA kit for DHEA and a species-independent ELISA kit for DHEA-S were tested against each other and available literature data. Blood samples were collected from 68 female broilers at slaughter. Most sample concentrations were close to the lower calibration range. DHEA concentrations ranged from 52 to 354 pg/mL, whereas DHEA-S values ranged from 76 to 7320 pg/mL. Both assays showed satisfactory validation results, including good precision (intra- and inter-assay CV ≤ 15%), accuracy (recovery ≥ 99%), linearity (R2 > 0.9; run test p > 0.1), and parallelism between calibrator curves and sample dilutions (ANCOVA p > 0.1). However, the DHEA-S assay showed high cross-reactivity with DHEA (160%), making quantitative DHEA-S determination unreliable; therefore, values should be interpreted as an estimate of combined DHEA/DHEA-S concentrations. Consequently, the higher concentrations measured with the DHEA-S ELISA compared with the DHEA RIA (Bland–Altman bias: −525.8 pg/mL) do not indicate a true predominance of DHEA-S. Nevertheless, both assays may represent useful tools for comparative evaluations among samples, although they do not provide reliable information on the physiological interconversion between the two steroids.

Authors

Institutions

Publication Details

Journal
Animals
Published
2026-06-27
DOI
https://doi.org/10.3390/ani16131990
Primary Topic
Hormonal and reproductive studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dehydroepiandrosterone (DHEA) and Dehydroepiandrosterone Sulfate (DHEA-S) in Broiler Plasma: Analytical Validation of Immunoassays and Comparative Overview Across Avian Species

Roberta Stocchi, Luca Todini, Marco Gobbi, Seyedalireza Kasaiyan et al.
Animals
Hormonal and reproductive studies
article

Dehydroepiandrosterone (DHEA) and Dehydroepiandrosterone Sulfate (DHEA-S) in Broiler Plasma: Analytical Validation of Immunoassays and Comparative Overview Across Avian Species

Roberta Stocchi, Luca Todini, Marco Gobbi, Seyedalireza Kasaiyan, Olimpia Barbato, Renzo Galli, Laura Menchetti, Giovanni Ricci
article en

Abstract

This study validated immunoassays for measuring circulating DHEA and DHEA-S in broiler plasma and compared the two biomarkers. A commercially available RIA kit for DHEA and a species-independent ELISA kit for DHEA-S were tested against each other and available literature data. Blood samples were collected from 68 female broilers at slaughter. Most sample concentrations were close to the lower calibration range. DHEA concentrations ranged from 52 to 354 pg/mL, whereas DHEA-S values ranged from 76 to 7320 pg/mL. Both assays showed satisfactory validation results, including good precision (intra- and inter-assay CV ≤ 15%), accuracy (recovery ≥ 99%), linearity (R2 > 0.9; run test p > 0.1), and parallelism between calibrator curves and sample dilutions (ANCOVA p > 0.1). However, the DHEA-S assay showed high cross-reactivity with DHEA (160%), making quantitative DHEA-S determination unreliable; therefore, values should be interpreted as an estimate of combined DHEA/DHEA-S concentrations. Consequently, the higher concentrations measured with the DHEA-S ELISA compared with the DHEA RIA (Bland–Altman bias: −525.8 pg/mL) do not indicate a true predominance of DHEA-S. Nevertheless, both assays may represent useful tools for comparative evaluations among samples, although they do not provide reliable information on the physiological interconversion between the two steroids.

AnimalsVol. 16(13)
Università di Camerino (IT), University of Perugia (IT), Cereal Research Centre (IT), Istituto Zooprofilattico Sperimentale dell'Umbria e delle Marche (IT)
Openalex Percentile: Top 7%
Hormonal and reproductive studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.