Evaluating the Performance of the TOP100 Tool in Detecting Key Small Bowel Findings at Capsule Endoscopy

Background/Objectives: Capsule endoscopy (CE) is a non-invasive tool for evaluating small bowel pathology, but prolonged reading times can lead to reader fatigue. Artificial intelligence-integrated reading software has shown promise to overcome this. This study assesses the diagnostic performance of TOP100 against standard human reading (SR) across different clinical indications. Methods: A retrospective single-centre cohort study was conducted at a tertiary referral centre, including patients who underwent PillCam™SB3 CE between January 2023 to August 2025. Initial reading was performed by expert CE readers (>1000 CE experience) considered as SR. Second blinded reading was performed with TOP100. CE findings from SR were compared with those from TOP100. Results: A total of 1382 CE were identified, of which 1374 had complete examinations and TOP100 data for analysis. The most common indications were inflammatory bowel disease (IBD) (51.5%) and iron-deficiency anaemia (IDA) (25.0%). Diagnostic yield was significantly higher with SR than TOP100 (36.0% vs. 27.5%, p < 0.001). TOP100 demonstrated moderate sensitivity but high specificity; 64.0% and 99.0% for active bleeding, 58.2% and 97.5% for angiodysplasia. In overt bleeding and IDA, sensitivity, and specificity for P2 lesions were 61.0% and 94.3%, respectively. Overall sensitivity and specificity were 55.3% and 95.9% for ulcers, 43.1% and 89.0% for erosions. In IBD, ulcer detection was similar, while TOP100 sensitivity for erosions improved by 9.4%. Conclusions: SR remains the reference standard for reading and reporting capsule endoscopies. However, TOP100 may be a useful adjunct to support interpretation and case prioritisation, especially in high-volume centres.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-06-27
DOI
https://doi.org/10.3390/diagnostics16132005
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the Performance of the TOP100 Tool in Detecting Key Small Bowel Findings at Capsule Endoscopy

Ailish Healy, Nicoletta Nandi, Victoria Thurston, Mark McAlindon et al.
Diagnostics
Gastrointestinal Bleeding Diagnosis and Treatment
article

Evaluating the Performance of the TOP100 Tool in Detecting Key Small Bowel Findings at Capsule Endoscopy

Ailish Healy, Nicoletta Nandi, Victoria Thurston, Mark McAlindon, Foong Way David Tai, Reena Sidhu, C Caranfil, Christian Bentley, Aishwarya Devanand, M Moore, Melissa Hale
article en

Abstract

Background/Objectives: Capsule endoscopy (CE) is a non-invasive tool for evaluating small bowel pathology, but prolonged reading times can lead to reader fatigue. Artificial intelligence-integrated reading software has shown promise to overcome this. This study assesses the diagnostic performance of TOP100 against standard human reading (SR) across different clinical indications. Methods: A retrospective single-centre cohort study was conducted at a tertiary referral centre, including patients who underwent PillCam™SB3 CE between January 2023 to August 2025. Initial reading was performed by expert CE readers (>1000 CE experience) considered as SR. Second blinded reading was performed with TOP100. CE findings from SR were compared with those from TOP100. Results: A total of 1382 CE were identified, of which 1374 had complete examinations and TOP100 data for analysis. The most common indications were inflammatory bowel disease (IBD) (51.5%) and iron-deficiency anaemia (IDA) (25.0%). Diagnostic yield was significantly higher with SR than TOP100 (36.0% vs. 27.5%, p < 0.001). TOP100 demonstrated moderate sensitivity but high specificity; 64.0% and 99.0% for active bleeding, 58.2% and 97.5% for angiodysplasia. In overt bleeding and IDA, sensitivity, and specificity for P2 lesions were 61.0% and 94.3%, respectively. Overall sensitivity and specificity were 55.3% and 95.9% for ulcers, 43.1% and 89.0% for erosions. In IBD, ulcer detection was similar, while TOP100 sensitivity for erosions improved by 9.4%. Conclusions: SR remains the reference standard for reading and reporting capsule endoscopies. However, TOP100 may be a useful adjunct to support interpretation and case prioritisation, especially in high-volume centres.

DiagnosticsVol. 16(13)
University of Padua (IT), Sheffield Teaching Hospitals NHS Foundation Trust (GB), University of Sheffield (GB)
Quality Education
Openalex Percentile: Top 5%
Gastrointestinal Bleeding Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.