Electrochemical Detection of Vanadium Using a Boron‐Doped Diamond Electrode as a Surrogate for Radioactive Heavy Metals

The release of radioactive heavy metals from radioisotope research laboratories necessitates rapid and on‐site analytical methods that complement conventional techniques such as inductively coupled plasma mass spectrometry (ICP‐MS) and accelerator mass spectrometry (AMS). In this study, a sensitive electrochemical detection method based on a boron‐doped diamond (BDD) electrode was developed in nitric acid media. Because experiments involving radioactive nuclides require specialized facilities, vanadium was employed as a nonradioactive surrogate to optimize anodic stripping voltammetry (ASV) conditions. Systematic optimization of experimental parameters, including electrolyte composition, electrode material, surface termination, and voltammetric method, identified ASV using an O‐terminated BDD electrode as the most effective approach. Under optimized conditions (deposition potential of −1.2 V [vs. Ag/AgCl] and deposition time of 180 s in 0.5 M HNO 3 ), a limit of detection (LOD) of 0.478 μM was achieved, outperforming CV, DPV, and SWV. Interference studies revealed that Ru(III) and Ce(III) significantly affect the vanadium signal but can be effectively mitigated by pH‐controlled precipitation and phosphoric acid addition, respectively. In contrast, Pd(II) interference remained unresolved due to its dominant electrochemical response. Finally, the applicability of the developed method to actinide‐relevant systems was demonstrated using a 237 Np solution, which exhibited a characteristic anodic signal at ~1.7 V (vs. Ag/AgCl), comparable to that of vanadium. These results highlight the potential of BDD‐based ASV for monitoring radioactive heavy metals in nitric‐acid environments.

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2026-06-28
DOI
https://doi.org/10.1002/elan.70182
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Detection of Vanadium Using a Boron‐Doped Diamond Electrode as a Surrogate for Radioactive Heavy Metals

Michio Murata, Yasuaki Einaga, Masaumi Nakahara, Mingwei Bai
Electroanalysis
Electrochemical Analysis and Applications
article

Electrochemical Detection of Vanadium Using a Boron‐Doped Diamond Electrode as a Surrogate for Radioactive Heavy Metals

Michio Murata, Yasuaki Einaga, Masaumi Nakahara, Mingwei Bai
article en

Abstract

The release of radioactive heavy metals from radioisotope research laboratories necessitates rapid and on‐site analytical methods that complement conventional techniques such as inductively coupled plasma mass spectrometry (ICP‐MS) and accelerator mass spectrometry (AMS). In this study, a sensitive electrochemical detection method based on a boron‐doped diamond (BDD) electrode was developed in nitric acid media. Because experiments involving radioactive nuclides require specialized facilities, vanadium was employed as a nonradioactive surrogate to optimize anodic stripping voltammetry (ASV) conditions. Systematic optimization of experimental parameters, including electrolyte composition, electrode material, surface termination, and voltammetric method, identified ASV using an O‐terminated BDD electrode as the most effective approach. Under optimized conditions (deposition potential of −1.2 V [vs. Ag/AgCl] and deposition time of 180 s in 0.5 M HNO 3 ), a limit of detection (LOD) of 0.478 μM was achieved, outperforming CV, DPV, and SWV. Interference studies revealed that Ru(III) and Ce(III) significantly affect the vanadium signal but can be effectively mitigated by pH‐controlled precipitation and phosphoric acid addition, respectively. In contrast, Pd(II) interference remained unresolved due to its dominant electrochemical response. Finally, the applicability of the developed method to actinide‐relevant systems was demonstrated using a 237 Np solution, which exhibited a characteristic anodic signal at ~1.7 V (vs. Ag/AgCl), comparable to that of vanadium. These results highlight the potential of BDD‐based ASV for monitoring radioactive heavy metals in nitric‐acid environments.

ElectroanalysisVol. 38(7)
Japan Atomic Energy Agency (JP), Keio University (JP)
Ministry of Economy, Trade and Industry, Japan Society for the Promotion of Science
Clean water and sanitation
Openalex Percentile: Top 17%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.