WiNGPT-32B: An Open-Source, Locally Deployable LLM for RECIST Assessment via Chained Task Execution Using Radiology Report Text

Objective: The objective of this study was to construct a large language model (LLM) for the Response Evaluation Criteria in Solid Tumors (RECIST) assessment using exclusively longitudinal radiology report text. Methods: This study included 258 patients with solid tumors, encompassing 2065 longitudinal CT/MRI examination time points. We developed WiNGPT-32B, an open-source and locally deployable LLM, by infusing it with domain-specific medical knowledge and optimizing it via knowledge distillation, using GPT-4 as the teacher model. Central to its architecture is the Chained Task Execution (CTE) framework, which structures RECIST assessment into four modular components: lesion diameter extraction, sum of longest diameter computation, tumor response classification, and report generation. Model performance (accuracy, recall, precision, and F1 score) was benchmarked against GPT-4 and a single radiologist, utilizing the consensus of three independent radiologists as the reference standard. Results: The number of patients with imaging time points was 212 (82.2%) with 4–10, 36 (13.9%) with 11–20, and 10 (3.9%) with >20 time points. For target lesions, the successful extraction rate of WiNGPT-32B was 0.934 (95% CI: 0.922–0.944), which was slightly higher than that of GPT-4 0.920 (0.907–0.931; p = 0.083). In five-category RECIST classification (complete response, partial response, stable disease, progressive disease, and not evaluable), WiNGPT-32B achieved an overall accuracy of 0.805 (0.786–0.823), significantly higher than GPT-4 (0.699, 0.678–0.720; p < 0.001) but lower than the radiologist (0.915, 0.901–0.928; p < 0.001). For progressive disease, WiNGPT-32B had an F1 score of 0.841 (0.813–0.870), significantly outperforming GPT-4’s 0.755 (0.720–0.790), and approaching the radiologist’s 0.922 (0.902–0.942). Conclusions: WiNGPT-32B demonstrates the feasibility of a text-only, open-source LLM with the CTE framework for longitudinal RECIST assessment, with promising performance in detecting disease progression.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-06-28
DOI
https://doi.org/10.3390/diagnostics16132020
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

WiNGPT-32B: An Open-Source, Locally Deployable LLM for RECIST Assessment via Chained Task Execution Using Radiology Report Text

Xueqian Xie, L Zhang, L L Zhang, Lingyun Wang et al.
Diagnostics
Radiomics and Machine Learning in Medical Imaging
article

WiNGPT-32B: An Open-Source, Locally Deployable LLM for RECIST Assessment via Chained Task Execution Using Radiology Report Text

Xueqian Xie, L Zhang, L L Zhang, Lingyun Wang, Yaping Zhang
article en

Abstract

Objective: The objective of this study was to construct a large language model (LLM) for the Response Evaluation Criteria in Solid Tumors (RECIST) assessment using exclusively longitudinal radiology report text. Methods: This study included 258 patients with solid tumors, encompassing 2065 longitudinal CT/MRI examination time points. We developed WiNGPT-32B, an open-source and locally deployable LLM, by infusing it with domain-specific medical knowledge and optimizing it via knowledge distillation, using GPT-4 as the teacher model. Central to its architecture is the Chained Task Execution (CTE) framework, which structures RECIST assessment into four modular components: lesion diameter extraction, sum of longest diameter computation, tumor response classification, and report generation. Model performance (accuracy, recall, precision, and F1 score) was benchmarked against GPT-4 and a single radiologist, utilizing the consensus of three independent radiologists as the reference standard. Results: The number of patients with imaging time points was 212 (82.2%) with 4–10, 36 (13.9%) with 11–20, and 10 (3.9%) with >20 time points. For target lesions, the successful extraction rate of WiNGPT-32B was 0.934 (95% CI: 0.922–0.944), which was slightly higher than that of GPT-4 0.920 (0.907–0.931; p = 0.083). In five-category RECIST classification (complete response, partial response, stable disease, progressive disease, and not evaluable), WiNGPT-32B achieved an overall accuracy of 0.805 (0.786–0.823), significantly higher than GPT-4 (0.699, 0.678–0.720; p < 0.001) but lower than the radiologist (0.915, 0.901–0.928; p < 0.001). For progressive disease, WiNGPT-32B had an F1 score of 0.841 (0.813–0.870), significantly outperforming GPT-4’s 0.755 (0.720–0.790), and approaching the radiologist’s 0.922 (0.902–0.942). Conclusions: WiNGPT-32B demonstrates the feasibility of a text-only, open-source LLM with the CTE framework for longitudinal RECIST assessment, with promising performance in detecting disease progression.

DiagnosticsVol. 16(13)
Tongren Hospital (CN)
National Natural Science Foundation of China
Quality Education
Openalex Percentile: Top 7%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.