From antimicrobial-impregnated to standard catheters for external ventricular drainage: a single-center before-and-after cohort study

BACKGROUND: The effectiveness of antibiotic-impregnated catheters (AIC) compared to standard catheters (SC) as external ventricular drains (EVD) for preventing EVD-related infections (ERI) is debated. In this study, we aimed to analyze the impact of a shift from AIC to SC, and so a de-escalation strategy, on ERI incidence rate. METHODS: This is a single-center before-and-after analysis of prospectively recorded data from consecutive patients treated in a French tertiary care hospital neurological intensive care unit from 2015 to 2020. Standard EVD handling procedure remained unchanged over study period, except for the first line drain, which was switched from AIC to SC in 2019. The main outcome was the difference in the incidence of ERI. RESULTS: Data from 510 consecutive patients (348 AIC, 162 SC) were analyzed. AIC use was associated with a lower incidence of ERI (2.6% vs 8.0% of ERI, 2.4 vs 6.8 ERI for 1000 catheterization days) and a delay in its onset (median delay from insertion of 11.0 [7.0-16.0] vs 7.0 [4.0-12.0] days, subdistribution hazard ratio sHR 0.32 [0.14-0.76], during follow-up period, p = 0.010). The presence of a cutaneous leakage, manipulations of EVD proximal stopcock, prolonged drainage duration and withdrawal motive were also associated with ERI diagnosis. Identified microorganisms according to Gram-staining did not differ with respect to catheter type, but the proportion of skin commensals is reduced using AIC (49.1 vs 68.9%, p = 0.047). CONCLUSIONS: Our findings suggest that AIC use as first intention catheter for CSF drainage was associated with a lower and delayed incidence of ERI. OTHERS: No funding was received for this study.

Authors

Institutions

Publication Details

Journal
Acta Neurochirurgica
Published
2026-06-27
DOI
https://doi.org/10.1007/s00701-026-06955-8
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From antimicrobial-impregnated to standard catheters for external ventricular drainage: a single-center before-and-after cohort study

Hervé Jacquier, Marc Zanello, Paul‐Louis Woerther, Ariane Roujansky et al.
Acta Neurochirurgica
Cerebrospinal fluid and hydrocephalus
article

From antimicrobial-impregnated to standard catheters for external ventricular drainage: a single-center before-and-after cohort study

Hervé Jacquier, Marc Zanello, Paul‐Louis Woerther, Ariane Roujansky, R Mounier, Jean Pasqueron, Fabrice Cook, Hatem Kallel, Maxime Thorn, Maxime T. Aparicio, Sylvain Diop
article en

Abstract

BACKGROUND: The effectiveness of antibiotic-impregnated catheters (AIC) compared to standard catheters (SC) as external ventricular drains (EVD) for preventing EVD-related infections (ERI) is debated. In this study, we aimed to analyze the impact of a shift from AIC to SC, and so a de-escalation strategy, on ERI incidence rate. METHODS: This is a single-center before-and-after analysis of prospectively recorded data from consecutive patients treated in a French tertiary care hospital neurological intensive care unit from 2015 to 2020. Standard EVD handling procedure remained unchanged over study period, except for the first line drain, which was switched from AIC to SC in 2019. The main outcome was the difference in the incidence of ERI. RESULTS: Data from 510 consecutive patients (348 AIC, 162 SC) were analyzed. AIC use was associated with a lower incidence of ERI (2.6% vs 8.0% of ERI, 2.4 vs 6.8 ERI for 1000 catheterization days) and a delay in its onset (median delay from insertion of 11.0 [7.0-16.0] vs 7.0 [4.0-12.0] days, subdistribution hazard ratio sHR 0.32 [0.14-0.76], during follow-up period, p = 0.010). The presence of a cutaneous leakage, manipulations of EVD proximal stopcock, prolonged drainage duration and withdrawal motive were also associated with ERI diagnosis. Identified microorganisms according to Gram-staining did not differ with respect to catheter type, but the proportion of skin commensals is reduced using AIC (49.1 vs 68.9%, p = 0.047). CONCLUSIONS: Our findings suggest that AIC use as first intention catheter for CSF drainage was associated with a lower and delayed incidence of ERI. OTHERS: No funding was received for this study.

Acta Neurochirurgica
École Nationale Vétérinaire d'Alfort (FR), Université Sorbonne Nouvelle (FR), Université Paris-Est Créteil (FR), Université Paris Cité (FR), University of French Guiana (GF), Sorbonne Université (FR), Université Sorbonne Paris Nord (FR), Systran (France) (FR), Hôpital Européen (FR), Centre Hospitalier Sud Francilien (FR), Centre Hospitalier Andrée Rosemon (GF), Hôpital Marie Lannelongue (FR), Centre Hospitalier Sainte-Anne (FR), Hôpital Avicenne (FR), Hôpitaux Universitaires Henri-Mondor (FR), FHU Neurovasc (FR), Université Gustave Eiffel (FR)
Openalex Percentile: Top 9%
Cerebrospinal fluid and hydrocephalus
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.