Successful Rescue of a Trapped Proglide by Balloon Angioplasty – A Case Report
Vascular closure devices (VCD) are commonly used for rapid haemostasis after femoral arterial cannulation, however, serious adverse events may rarely occur. We describe a case where use of Perclose Proglide for closure of the right femoral artery (RFA) access site led to focal arterial dissection, entrapping the footplate of a second Proglide device during staged percutaneous coronary intervention (PCI). The trapped device was eventually extracted using intravascular ultrasound (IVUS)-guided balloon angioplasty with cross-over approach. This case highlights the potential complications of VCD and possible endovascular strategies in tackling such issues.
Authors
- Cheuk Yin Lai
- GuangMing Tan (ORCID: https://orcid.org/0000-0001-6828-6269)
Institutions
- Chinese University of Hong Kong (HK)
- Prince of Wales Hospital (CN)
Publication Details
- Journal
- Journal of the Hong Kong College of Cardiology
- Published
- 2026-06-26
- DOI
- https://doi.org/10.55503/2790-6744.1588
- Primary Topic
- Vascular Procedures and Complications
- Type
- article
- Field-Weighted Citation Impact
- 0.00