Comparative evaluation of radiological anatomy knowledge and accuracy of <scp>ChatGPT</scp> ‐5, Gemini 2.5, and Grok 4 across normal and thinking modes

This study compared the performance of three large language models, ChatGPT-5 Plus, Gemini 2.5 Pro, and SuperGrok 4, in identifying anatomical structures on radiographic images using standardized anatomical terminology. Thirty radiographs from different body regions were selected from an open-access atlas and analyzed by the models in Normal and Thinking modes using standardized prompts based on Terminologia Anatomica (version 2.07). Responses were evaluated independently by two anatomists using a 0-2 scoring system. Overall accuracy across both modes and models ranged from 47.4% to 85.7%. Data were analyzed using Friedman and Wilcoxon signed-rank tests. Temporal response consistency was assessed with weighted kappa coefficients. Gemini 2.5 Pro and ChatGPT-5 Plus significantly outperformed SuperGrok 4 in both modes. In Normal mode, Gemini 2.5 Pro achieved the highest overall accuracy (82.7%), significantly exceeding ChatGPT-5 Plus (60.7%, p = 0.001) and SuperGrok 4 (47.4%, p < 0.001). In Thinking mode, accuracies were 85.7% for Gemini 2.5 Pro, 77.6% for ChatGPT-5 Plus, and 49.5% for SuperGrok 4. Gemini 2.5 Pro demonstrated a significant advantage over ChatGPT-5 Plus only in Normal mode (p = 0.001), whereas Thinking mode significantly improved performance only for ChatGPT-5 Plus (p = 0.01). Temporal stability analysis showed high response consistency for Gemini 2.5 Pro and SuperGrok 4 across all modes (r > 0.94, p < 0.001). Conversely, ChatGPT-5 Plus' stability decreased from substantial agreement in normal mode (r = 0.697, p < 0.001) to moderate agreement in Thinking mode (r = 0.539, p < 0.001). Despite their educational potential, these models need refinement to reliably identify anatomical structures on radiographic images.

Authors

Institutions

Publication Details

Journal
Anatomical Sciences Education
Published
2026-06-26
DOI
https://doi.org/10.1002/ase.70292
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative evaluation of radiological anatomy knowledge and accuracy of ChatGPT ‐5, Gemini 2.5, and Grok 4 across normal and thinking modes

Halit Çeli̇k, Tuncay Çolak, İsmail Sivri, Furkan Mehmet Özden et al.
Anatomical Sciences Education
Artificial Intelligence in Healthcare and Education
article

Comparative evaluation of radiological anatomy knowledge and accuracy of ChatGPT ‐5, Gemini 2.5, and Grok 4 across normal and thinking modes

Halit Çeli̇k, Tuncay Çolak, İsmail Sivri, Furkan Mehmet Özden, ÖZGÜR GÖKTÜRK
article en

Abstract

This study compared the performance of three large language models, ChatGPT-5 Plus, Gemini 2.5 Pro, and SuperGrok 4, in identifying anatomical structures on radiographic images using standardized anatomical terminology. Thirty radiographs from different body regions were selected from an open-access atlas and analyzed by the models in Normal and Thinking modes using standardized prompts based on Terminologia Anatomica (version 2.07). Responses were evaluated independently by two anatomists using a 0-2 scoring system. Overall accuracy across both modes and models ranged from 47.4% to 85.7%. Data were analyzed using Friedman and Wilcoxon signed-rank tests. Temporal response consistency was assessed with weighted kappa coefficients. Gemini 2.5 Pro and ChatGPT-5 Plus significantly outperformed SuperGrok 4 in both modes. In Normal mode, Gemini 2.5 Pro achieved the highest overall accuracy (82.7%), significantly exceeding ChatGPT-5 Plus (60.7%, p = 0.001) and SuperGrok 4 (47.4%, p < 0.001). In Thinking mode, accuracies were 85.7% for Gemini 2.5 Pro, 77.6% for ChatGPT-5 Plus, and 49.5% for SuperGrok 4. Gemini 2.5 Pro demonstrated a significant advantage over ChatGPT-5 Plus only in Normal mode (p = 0.001), whereas Thinking mode significantly improved performance only for ChatGPT-5 Plus (p = 0.01). Temporal stability analysis showed high response consistency for Gemini 2.5 Pro and SuperGrok 4 across all modes (r > 0.94, p < 0.001). Conversely, ChatGPT-5 Plus' stability decreased from substantial agreement in normal mode (r = 0.697, p < 0.001) to moderate agreement in Thinking mode (r = 0.539, p < 0.001). Despite their educational potential, these models need refinement to reliably identify anatomical structures on radiographic images.

Anatomical Sciences Education
Kocaeli Üniversitesi (TR)
Quality Education
Openalex Percentile: Top 9%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.