When “Noise” Isn’t Simply Noise: Deterministic Postural Drive During Noisy Galvanic Vestibular Stimulation (nGVS)

Age- and disease-related vestibular decline contributes to dizziness and postural instability, motivating interventions such as noisy galvanic vestibular stimulation (nGVS). nGVS is often applied at imperceptible amplitudes and interpreted through a stochastic resonance (SR) mechanism, but because galvanic stimulation directly modulates vestibular afferents, even imperceptible currents may deterministically influence balance. The present study tested whether low nGVS stimulus amplitudes (< 1mA), commonly used in stochastic resonance paradigms, directly drive postural behavior. Twenty healthy young adults stood on a force plate with feet together and eyes closed under two surface conditions (rigid and 10-cm foam). Participants completed 300-s trials with band-limited (0-30 Hz), zero-mean nGVS at ±0, 0.1, 0.2, 0.3, 0.5, and 0.7 mA in randomized order. Coupling between the stimulation waveform and mediolateral ground-reaction force was quantified using coherence and time-cumulant density. Group mean coherence became significant primarily at higher amplitudes (0.5-0.7 mA) for both surfaces, while time-cumulant density revealed significant time-locked vestibular-evoked response components beginning at much lower amplitudes (down to 0.1 mA), including an early component (~135-155 ms) and a later prominent component (~360-410 ms). Individually, significant coherence was prevalent at 0.5-0.7 mA (15-19 of 20 participants, depending on surface and amplitude), whereas cumulant-based responses were observed in a subset as low as 0.1 mA. Responses were more evident on foam, consistent with increased vestibular reliance under reduced somatosensory reliability. These findings show that low-amplitude nGVS can produce stimulus-locked postural output, implying that balance changes during imperceptible nGVS amplitudes may reflect deterministic vestibular drive, SR-like facilitation, or both.

Authors

Institutions

Publication Details

Journal
Journal of Neurophysiology
Published
2026-06-27
DOI
https://doi.org/10.1152/jn.00177.2026
Primary Topic
Vestibular and auditory disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

When “Noise” Isn’t Simply Noise: Deterministic Postural Drive During Noisy Galvanic Vestibular Stimulation (nGVS)

Dominique Rice, Kelci B. Hannan, Christopher J. Dakin, Malynn Ewer
Journal of Neurophysiology
Vestibular and auditory disorders
article

When “Noise” Isn’t Simply Noise: Deterministic Postural Drive During Noisy Galvanic Vestibular Stimulation (nGVS)

Dominique Rice, Kelci B. Hannan, Christopher J. Dakin, Malynn Ewer
article en

Abstract

Age- and disease-related vestibular decline contributes to dizziness and postural instability, motivating interventions such as noisy galvanic vestibular stimulation (nGVS). nGVS is often applied at imperceptible amplitudes and interpreted through a stochastic resonance (SR) mechanism, but because galvanic stimulation directly modulates vestibular afferents, even imperceptible currents may deterministically influence balance. The present study tested whether low nGVS stimulus amplitudes (< 1mA), commonly used in stochastic resonance paradigms, directly drive postural behavior. Twenty healthy young adults stood on a force plate with feet together and eyes closed under two surface conditions (rigid and 10-cm foam). Participants completed 300-s trials with band-limited (0-30 Hz), zero-mean nGVS at ±0, 0.1, 0.2, 0.3, 0.5, and 0.7 mA in randomized order. Coupling between the stimulation waveform and mediolateral ground-reaction force was quantified using coherence and time-cumulant density. Group mean coherence became significant primarily at higher amplitudes (0.5-0.7 mA) for both surfaces, while time-cumulant density revealed significant time-locked vestibular-evoked response components beginning at much lower amplitudes (down to 0.1 mA), including an early component (~135-155 ms) and a later prominent component (~360-410 ms). Individually, significant coherence was prevalent at 0.5-0.7 mA (15-19 of 20 participants, depending on surface and amplitude), whereas cumulant-based responses were observed in a subset as low as 0.1 mA. Responses were more evident on foam, consistent with increased vestibular reliance under reduced somatosensory reliability. These findings show that low-amplitude nGVS can produce stimulus-locked postural output, implying that balance changes during imperceptible nGVS amplitudes may reflect deterministic vestibular drive, SR-like facilitation, or both.

Journal of Neurophysiology
Utah State University (US)
Good health and well-being
Openalex Percentile: Top 8%
Vestibular and auditory disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.