Can we assess exercise metabolism from skin? Metabolomic profiles in skin dialysate collected during exercise

Monitoring exercise intensity is essential for optimizing the health benefits of physical activity. Indirect calorimetry is the gold-standard method for assessing metabolic stress during exercise, though, its reliance on extensive equipment for sampling and analyzing exhaled gases restricts its widespread application. Skin interstitial fluid may represent an ideal biofluid for the continuous monitoring of whole-body metabolism and exercise intensity. However, specific metabolites in skin interstitial fluid that are more closely associated with metabolic variables measured by indirect calorimetry remain unknown. We examined which metabolites in skin interstitial fluid most closely reflect metabolic responses assessed by indirect calorimetry during a continuous graded exercise protocol. Twelve young participants (5 females) exercised at low, moderate, and high-intensity phases (25%, 50%, and 75% VO₂peak), each lasting 20 min. Skin dialysate, which reflects the composition of skin interstitial fluid, were collected via intradermal microdialysis during each exercise, and metabolites in the dialysate were measured and analyzed. Medium- and long-chain acylcarnitines in skin dialysate increased during moderate-intensity exercise in line with elevations in whole-body fat oxidation. During high-intensity phase, lactic acid in skin dialysate was elevated along with increases in whole-body carbohydrate oxidation. Many metabolites including those mentioned above in skin dialysate were correlated with whole-body metabolic responses. Our preliminary data suggest that metabolite concentrations in skin interstitial fluid may be associated with variables measured by indirect calorimetry. These findings may inform the future development of wearable devices that could potentially be used for continuous and noninvasive monitoring of exercise intensity.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physiology
Published
2026-06-27
DOI
https://doi.org/10.1152/japplphysiol.01017.2025
Primary Topic
thermodynamics and calorimetric analyses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can we assess exercise metabolism from skin? Metabolomic profiles in skin dialysate collected during exercise

Takeshi Nishiyasu, Katsuhiko Yajima, Taito Murakami, Naoto Fujii et al.
Journal of Applied Physiology
thermodynamics and calorimetric analyses
article

Can we assess exercise metabolism from skin? Metabolomic profiles in skin dialysate collected during exercise

Takeshi Nishiyasu, Katsuhiko Yajima, Taito Murakami, Naoto Fujii, Koichi Watanabe, Gulinu Maimaituxun, Shota Mitsuhashi
article en

Abstract

Monitoring exercise intensity is essential for optimizing the health benefits of physical activity. Indirect calorimetry is the gold-standard method for assessing metabolic stress during exercise, though, its reliance on extensive equipment for sampling and analyzing exhaled gases restricts its widespread application. Skin interstitial fluid may represent an ideal biofluid for the continuous monitoring of whole-body metabolism and exercise intensity. However, specific metabolites in skin interstitial fluid that are more closely associated with metabolic variables measured by indirect calorimetry remain unknown. We examined which metabolites in skin interstitial fluid most closely reflect metabolic responses assessed by indirect calorimetry during a continuous graded exercise protocol. Twelve young participants (5 females) exercised at low, moderate, and high-intensity phases (25%, 50%, and 75% VO₂peak), each lasting 20 min. Skin dialysate, which reflects the composition of skin interstitial fluid, were collected via intradermal microdialysis during each exercise, and metabolites in the dialysate were measured and analyzed. Medium- and long-chain acylcarnitines in skin dialysate increased during moderate-intensity exercise in line with elevations in whole-body fat oxidation. During high-intensity phase, lactic acid in skin dialysate was elevated along with increases in whole-body carbohydrate oxidation. Many metabolites including those mentioned above in skin dialysate were correlated with whole-body metabolic responses. Our preliminary data suggest that metabolite concentrations in skin interstitial fluid may be associated with variables measured by indirect calorimetry. These findings may inform the future development of wearable devices that could potentially be used for continuous and noninvasive monitoring of exercise intensity.

Journal of Applied Physiology
University of Tsukuba (JP), Josai University (JP)
Good health and well-being
Openalex Percentile: Top 7%
thermodynamics and calorimetric analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.