FeuNet: cross-user gesture recognition and fingertip force estimation network based on feature enhancement and U-Net

Surface electromyography (sEMG)-based gesture recognition and fingertip force estimation are widely applied, but cross-user generalization remains challenging. This paper proposes FeuNet, a deep learning network integrating a feature enhancement module and a sEU-Net architecture for sEMG representation and shallow feature mapping. Furthermore, an adaptive loss function balances the optimization of both tasks. With calibration using 50% of the new user's data, FeuNet achieved 78.97% recognition accuracy, alongside a 5.51% normalized root mean square error and 67.12% coefficient of determination. Compared with existing methods, FeuNet improves both cross-user performance and calibration efficiency.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2026-06-26
DOI
https://doi.org/10.1080/10255842.2026.2689699
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FeuNet: cross-user gesture recognition and fingertip force estimation network based on feature enhancement and U-Net

Q Y Wang, Huasong Min, Zhaoxu Luan
Computer Methods in Biomechanics & Biomedical Engineering
Muscle activation and electromyography studies
article

FeuNet: cross-user gesture recognition and fingertip force estimation network based on feature enhancement and U-Net

Q Y Wang, Huasong Min, Zhaoxu Luan
article en

Abstract

Surface electromyography (sEMG)-based gesture recognition and fingertip force estimation are widely applied, but cross-user generalization remains challenging. This paper proposes FeuNet, a deep learning network integrating a feature enhancement module and a sEU-Net architecture for sEMG representation and shallow feature mapping. Furthermore, an adaptive loss function balances the optimization of both tasks. With calibration using 50% of the new user's data, FeuNet achieved 78.97% recognition accuracy, alongside a 5.51% normalized root mean square error and 67.12% coefficient of determination. Compared with existing methods, FeuNet improves both cross-user performance and calibration efficiency.

Computer Methods in Biomechanics & Biomedical Engineering
Wuhan University of Science and Technology (CN)
Openalex Percentile: Top 11%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.