Separated flow and heat transfer behind a single rib in an annular gap between rotating cylinders

The results of a numerical study of laminar liquid flow and heat transfer in an annular gap between two cylinders with a rib on one of the walls are presented. A mechanism for intensifying heat transfer between two cylinders, when one is rotating, was studied. Intensification was achieved by installing a single rib on the inner or outer cylinder. The rib was oriented along the annular system radius and occupied half the height of the gap between cylinders. The problem was formulated in two dimensions. The Reynolds number was varied in the range from 100 to 1000. Air was the working medium. Four options for the location of the intensifying rib were considered. A fundamental difference in the structure of the recirculation zone was noted for different rib locations. Maximum heat transfer was achieved on the wall of the stationary cylinder opposite the rib mounted on the rotating cylinder. Its multiple increase was observed compared to the case of rotating smooth cylinders.

Authors

Institutions

Publication Details

Journal
Thermophysics and Aeromechanics
Published
2026-06-27
DOI
https://doi.org/10.1134/s0869864325060010
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Separated flow and heat transfer behind a single rib in an annular gap between rotating cylinders

V.V. Terekhov, Т.В. Богатко, V. I. Terekhov
Thermophysics and Aeromechanics
Heat Transfer Mechanisms
article

Separated flow and heat transfer behind a single rib in an annular gap between rotating cylinders

V.V. Terekhov, Т.В. Богатко, V. I. Terekhov
article en

Abstract

The results of a numerical study of laminar liquid flow and heat transfer in an annular gap between two cylinders with a rib on one of the walls are presented. A mechanism for intensifying heat transfer between two cylinders, when one is rotating, was studied. Intensification was achieved by installing a single rib on the inner or outer cylinder. The rib was oriented along the annular system radius and occupied half the height of the gap between cylinders. The problem was formulated in two dimensions. The Reynolds number was varied in the range from 100 to 1000. Air was the working medium. Four options for the location of the intensifying rib were considered. A fundamental difference in the structure of the recirculation zone was noted for different rib locations. Maximum heat transfer was achieved on the wall of the stationary cylinder opposite the rib mounted on the rotating cylinder. Its multiple increase was observed compared to the case of rotating smooth cylinders.

Thermophysics and AeromechanicsVol. 32(6)
Institute of Thermophysics (RU)
Openalex Percentile: Top 12%
Heat Transfer Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.