Ultrasound-based assessment of peri-implant mucosal thickness: an ex vivo comparative study with artificial intelligence-assisted image analysis
BACKGROUND: Mucosal thickness (MT) is a key factor influencing peri-implant soft-tissue response and outcomes in dental implantology. This ex vivo study evaluated the agreement of peri-implant MT measurements obtained using ultrasound (US) standardized with a custom probe holder, compared with transgingival probing (TP) and cone-beam computed tomography (CBCT). METHODS: Porcine hemimandibles (n = 18) underwent guided implant placement. MT was measured at five standardized points using four approaches: (1) US with expert annotation, (2) US with artificial intelligence (AI)-based image segmentation, (3) CBCT, and (4) TP. US images (17 MHz) were independently annotated by two trained specialists; a deep-learning-based method was used to derive automated MT measurements. Method differences were analyzed using a linear mixed-effects model; agreement was assessed using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. RESULTS: The overall method effect was not significant (p = 0.105). Pairwise comparisons showed no significant difference between expert-annotated US and TP (p = 0.328), whereas CBCT yielded higher MT values than TP (p = 0.035). Agreement was moderate for expert-annotated US versus TP (ICC = 0.58; 95% confidence interval (CI): 0.42-0.70) and for expert-annotated US versus AI-segmented US (ICC = 0.67; 95% CI: 0.53-0.77), but poor for expert-annotated US versus CBCT (ICC = 0.14; 95% CI: -0.05-0.33). Bland-Altman analysis showed mean differences (95% limits of agreement) of 0.08 mm (- 0.96 mm to + 1.13 mm) for expert-annotated US - TP, - 0.01 mm (- 0.68 mm to + 0.67 mm) for expert-annotated US-AI-segmented US, and - 0.30 mm (- 2.29 mm to + 1.68 mm) for expert-annotated US-CBCT. CONCLUSIONS: Under controlled ex vivo conditions, expert-annotated US standardized with a custom probe holder showed moderate comparative agreement with TP, while AI-segmented measurements showed moderate agreement with expert annotation. CBCT showed limited agreement with US. This integrated approach represents a proof-of-concept requiring further in vivo validation.
Authors
- Klaus Radermacher (ORCID: https://orcid.org/0000-0003-4395-3197)
- Nikol Petrova
- Stefan Wolfart
- Peter Broessner
- Fabian Christleven
- Juliana Marotti
Institutions
- Medical University of Graz (AT)
- RWTH Aachen University (DE)
- FH Aachen (DE)
Publication Details
- Journal
- BMC Oral Health
- Published
- 2026-06-27
- DOI
- https://doi.org/10.1186/s12903-026-08665-0
- Primary Topic
- Dental Implant Techniques and Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- RWTH Aachen University