Tender X-ray Coherence Characterization at Beamline BM44 of the High Energy Photon Source

High Resolution Image Download MS PowerPoint Slide A method for characterizing the spatial coherence of tender X-ray radiation using a single diffraction pattern is presented. The technique is based on scattering from a non-redundant array (NRA) of slits. It is used to measure the degree of spatial coherence at beamline BM44 (Tender X-ray Beamline) of the High Energy Photon Source. To verify the results, a Young’s double-slit experiment was also performed. This paper reports the coherence lengths obtained using both methods and provides a comparison and analysis of the two approaches. For the Tender X-ray Beamline, the measured vertical coherence length is 12.1±0.7μm using the NRA method, compared to 14.4±0.6μm derived from the Young’s double-slit experiment.

Authors

Institutions

Publication Details

Journal
Photon Science
Published
2026-06-27
DOI
https://doi.org/10.1021/photonsci.6c00019
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tender X-ray Coherence Characterization at Beamline BM44 of the High Energy Photon Source

Tianchong Zhang, Shuhu Liu, Y ZHAO, Yongyang Wang et al.
Photon Science
Advanced X-ray Imaging Techniques
article

Tender X-ray Coherence Characterization at Beamline BM44 of the High Energy Photon Source

Tianchong Zhang, Shuhu Liu, Y ZHAO, Yongyang Wang, X Zhao, C W, Lei Zheng, Kun Tang, Jianmin Li, Dongmei Liu
article en

Abstract

High Resolution Image Download MS PowerPoint Slide A method for characterizing the spatial coherence of tender X-ray radiation using a single diffraction pattern is presented. The technique is based on scattering from a non-redundant array (NRA) of slits. It is used to measure the degree of spatial coherence at beamline BM44 (Tender X-ray Beamline) of the High Energy Photon Source. To verify the results, a Young’s double-slit experiment was also performed. This paper reports the coherence lengths obtained using both methods and provides a comparison and analysis of the two approaches. For the Tender X-ray Beamline, the measured vertical coherence length is 12.1±0.7μm using the NRA method, compared to 14.4±0.6μm derived from the Young’s double-slit experiment.

Photon Science
Chinese Academy of Sciences (CN), University of Chinese Academy of Sciences (CN)
Affordable and clean energy
Openalex Percentile: Top 6%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.