Finite-element study on the function relationship between knee sleeve pressure and body surface displacement and the point position of the leg cross-section

Knee sleeves are one of the most essential protective items for sports enthusiasts. By exerting pressure on the leg during wear, knee sleeves help reduce muscle vibration, providing protection to the human body while effectively enhancing athletic performance. However, most knee sleeve products currently on the market commonly suffer from issues such as imperfect functionality, pressure distribution that does not conform to human body shape characteristics, and an inability to meet the wearer’s needs for exercise and comfort. To improve the functionality and pressure comfort of knee sleeves after wearing, this study established a three-dimensional finite-element model of the human knee joint based on CT images. Geometric models of the “knee sleeve–knee joint” were constructed using MIMICS and Solidworks. Thirty subjects were selected to wear five types of experimental knee sleeves with different structural designs, and pressure tests were conducted to validate the effectiveness of the finite-element model. To further explore the relationship between pressure and human body surface displacement during knee sleeve wear, displacement data from 16 test points on five cross sections of the human knee joint were extracted through finite-element simulation. The results show that the peak pressure was located at the anterior test points where bones protrude, while the peak displacement was located at the posterior test points with thicker soft tissue, exhibiting a nonlinear relationship between the two. To further quantify the functional relationship among pressure, body surface displacement, and leg cross-sectional points, this study established fitting equations of “pressure/displacement versus leg cross-sectional test points” for each cross section of the knee joint, enabling accurate prediction of human body surface displacement based on pressure values. These conclusions provide a theoretical reference and data support for optimizing the balance between functionality and comfort of knee sleeves in accordance with human physiological characteristics.

Authors

Institutions

Publication Details

Journal
Textile Research Journal
Published
2026-06-25
DOI
https://doi.org/10.1177/00405175261459195
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite-element study on the function relationship between knee sleeve pressure and body surface displacement and the point position of the leg cross-section

Riwei Chen, Huihong Gu, Rui Dan, Zhen Shi et al.
Textile Research Journal
Muscle activation and electromyography studies
article

Finite-element study on the function relationship between knee sleeve pressure and body surface displacement and the point position of the leg cross-section

Riwei Chen, Huihong Gu, Rui Dan, Zhen Shi, Tian Fan, Xinyu Zhao
article en

Abstract

Knee sleeves are one of the most essential protective items for sports enthusiasts. By exerting pressure on the leg during wear, knee sleeves help reduce muscle vibration, providing protection to the human body while effectively enhancing athletic performance. However, most knee sleeve products currently on the market commonly suffer from issues such as imperfect functionality, pressure distribution that does not conform to human body shape characteristics, and an inability to meet the wearer’s needs for exercise and comfort. To improve the functionality and pressure comfort of knee sleeves after wearing, this study established a three-dimensional finite-element model of the human knee joint based on CT images. Geometric models of the “knee sleeve–knee joint” were constructed using MIMICS and Solidworks. Thirty subjects were selected to wear five types of experimental knee sleeves with different structural designs, and pressure tests were conducted to validate the effectiveness of the finite-element model. To further explore the relationship between pressure and human body surface displacement during knee sleeve wear, displacement data from 16 test points on five cross sections of the human knee joint were extracted through finite-element simulation. The results show that the peak pressure was located at the anterior test points where bones protrude, while the peak displacement was located at the posterior test points with thicker soft tissue, exhibiting a nonlinear relationship between the two. To further quantify the functional relationship among pressure, body surface displacement, and leg cross-sectional points, this study established fitting equations of “pressure/displacement versus leg cross-sectional test points” for each cross section of the knee joint, enabling accurate prediction of human body surface displacement based on pressure values. These conclusions provide a theoretical reference and data support for optimizing the balance between functionality and comfort of knee sleeves in accordance with human physiological characteristics.

Textile Research Journal
Qingdao University (CN)
Openalex Percentile: Top 11%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.