Indoor air exposure to brominated flame retardants in public primary schools and associations with childhood respiratory and skin outcomes

Despite widespread use of polybrominated diphenyl ethers (PBDEs) and other brominated flame retardants (BFRs) in indoor environments, data on children's BFR exposure in Portuguese schools and associated health effects remain limited. We aimed to characterize indoor air BFR concentrations in 20 Portuguese primary schools, examine grade-specific exposure patterns, and investigate the associations between BFR concentrations and childhood asthma, wheezing, and eczema. Air BFRs were measured using passive sampling in 80 classrooms over 28 days. Health outcomes (lifetime asthma history, current asthma, wheezing, and eczema) were obtained from standardized parental questionnaires. Multilevel logistic regression models accounting for school-level clustering evaluated associations between log-transformed concentrations and health outcomes, adjusting for relevant confounders. The sum of BFR (∑BFR) concentrations ranged between 28.12 and 154.54 pg/m³ . Replacement BFRs, particularly decabromodiphenyl ethane (DBDPE), were dominant contributors, while BDE-47 and BDE-209 remained prevalent among legacy compounds. Grade 1 students exhibited higher exposure to several BFRs than older students. Per log10-unit increase, BDE-209 was associated with higher odds of lifetime asthma history (OR=2.13; 1.09-5.11) and wheezing (OR=1.75; 1.17-3.18), while an increase in ∑BFRs (OR=1.93; 1.29-3.91) was associated with higher odds of current asthma. Furthermore, a log10-unit increase in ∑non-BDEs was associated with a significantly higher eczema odds (OR=2.88; 1.65-5.46). Children in schools are exposed to legacy and replacement BFRs, with patterns varying per grade. The prominence of replacement compounds underscores an ongoing transition in indoor BFR profiles, reinforcing the need for targeted mitigation strategies and continued evaluation of potential health risks to children.

Authors

Institutions

Publication Details

Journal
Journal of Hazardous Materials
Published
2026-06-26
DOI
https://doi.org/10.1016/j.jhazmat.2026.142814
Primary Topic
Air Quality and Health Impacts
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Indoor air exposure to brominated flame retardants in public primary schools and associations with childhood respiratory and skin outcomes

Georges Hatem, João Paulo Teixeira, Amina Salamova, Minghao Kong et al.
Journal of Hazardous Materials
Air Quality and Health Impacts
article

Indoor air exposure to brominated flame retardants in public primary schools and associations with childhood respiratory and skin outcomes

Georges Hatem, João Paulo Teixeira, Amina Salamova, Minghao Kong, Maria do Carmo Pereira, Klára Slezáková, Joana Madureira, Otto Hänninen, Ana Margarida Faria, Carla Costa
article en

Abstract

Despite widespread use of polybrominated diphenyl ethers (PBDEs) and other brominated flame retardants (BFRs) in indoor environments, data on children's BFR exposure in Portuguese schools and associated health effects remain limited. We aimed to characterize indoor air BFR concentrations in 20 Portuguese primary schools, examine grade-specific exposure patterns, and investigate the associations between BFR concentrations and childhood asthma, wheezing, and eczema. Air BFRs were measured using passive sampling in 80 classrooms over 28 days. Health outcomes (lifetime asthma history, current asthma, wheezing, and eczema) were obtained from standardized parental questionnaires. Multilevel logistic regression models accounting for school-level clustering evaluated associations between log-transformed concentrations and health outcomes, adjusting for relevant confounders. The sum of BFR (∑BFR) concentrations ranged between 28.12 and 154.54 pg/m³ . Replacement BFRs, particularly decabromodiphenyl ethane (DBDPE), were dominant contributors, while BDE-47 and BDE-209 remained prevalent among legacy compounds. Grade 1 students exhibited higher exposure to several BFRs than older students. Per log10-unit increase, BDE-209 was associated with higher odds of lifetime asthma history (OR=2.13; 1.09-5.11) and wheezing (OR=1.75; 1.17-3.18), while an increase in ∑BFRs (OR=1.93; 1.29-3.91) was associated with higher odds of current asthma. Furthermore, a log10-unit increase in ∑non-BDEs was associated with a significantly higher eczema odds (OR=2.88; 1.65-5.46). Children in schools are exposed to legacy and replacement BFRs, with patterns varying per grade. The prominence of replacement compounds underscores an ongoing transition in indoor BFR profiles, reinforcing the need for targeted mitigation strategies and continued evaluation of potential health risks to children.

Journal of Hazardous MaterialsVol. 514
Emory University (US), Universidade do Porto (PT), National Institute of Health Dr. Ricardo Jorge (PT), University of Oulu (FI)
National Institutes of Health, Fundação para a Ciência e a Tecnologia
Openalex Percentile: Top 8%
Air Quality and Health Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.