Experimental Investigation of Pressure Drop in Pipe Flow with Standard Fittings at Varying Reynolds Numbers

Pipe fittings elbows, tee junctions, gate valves, and sudden expansions account for a significant fraction of total pressure loss in industrial piping systems, often exceeding the friction losses in straight pipe sections for compact installations. This experimental study measures the pressure drop and loss coefficient across five standard pipe fittings in a 25 mm internal diameter PVC pipe system over a Reynolds number range of 8,000 to 48,000 (turbulent flow). An open-circuit water flow loop equipped with a calibrated electromagnetic flow meter, differential pressure transducers, and thermocouples provided controlled test conditions. Loss coefficients (K-values) were determined experimentally and compared with published Crane Technical Paper 410 values. A 90-degree elbow showed the highest K value of 1.8 among the fittings tested, while a fully open gate valve gave the lowest at 0.18. The experimental K values agreed with published data within 7.4 percent mean absolute error across all fittings and flow rates. A simple correlation between K and Reynolds number is proposed for the tested fittings, valid for Re between 10,000 and 48,000.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-06-26
DOI
https://doi.org/10.5281/zenodo.20917486
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Investigation of Pressure Drop in Pipe Flow with Standard Fittings at Varying Reynolds Numbers

S. Mulani, S. S. Patil
Zenodo (CERN European Organization for Nuclear Research)
Flow Measurement and Analysis
article

Experimental Investigation of Pressure Drop in Pipe Flow with Standard Fittings at Varying Reynolds Numbers

S. Mulani, S. S. Patil
article en

Abstract

Pipe fittings elbows, tee junctions, gate valves, and sudden expansions account for a significant fraction of total pressure loss in industrial piping systems, often exceeding the friction losses in straight pipe sections for compact installations. This experimental study measures the pressure drop and loss coefficient across five standard pipe fittings in a 25 mm internal diameter PVC pipe system over a Reynolds number range of 8,000 to 48,000 (turbulent flow). An open-circuit water flow loop equipped with a calibrated electromagnetic flow meter, differential pressure transducers, and thermocouples provided controlled test conditions. Loss coefficients (K-values) were determined experimentally and compared with published Crane Technical Paper 410 values. A 90-degree elbow showed the highest K value of 1.8 among the fittings tested, while a fully open gate valve gave the lowest at 0.18. The experimental K values agreed with published data within 7.4 percent mean absolute error across all fittings and flow rates. A simple correlation between K and Reynolds number is proposed for the tested fittings, valid for Re between 10,000 and 48,000.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 11%
Flow Measurement and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.