Does Counterclockwise Rotation Affect Fixation Stability? An In Vitro Biomechanical Study of Large Mandibular Advancements

The selection of an appropriate fixation system is critical for maintaining postoperative stability after sagittal split ramus osteotomy (SSRO), especially in cases involving large mandibular advancements and counterclockwise rotation, where mechanical stresses may compromise treatment outcomes. This in vitro study evaluated the biomechanical stability of five fixation systems following sagittal split ramus osteotomy (SSRO) under two mandibular advancement conditions. Fifty polyurethane hemimandibles were allocated into two experimental groups: Group 1, submitted to 10-mm linear advancement, and Group 2, submitted to 10-mm advancement associated with 20° counterclockwise rotation. Each group was further divided into five subgroups according to the fixation design employed: (A) conventional straight plate, (B) angled plate, (C) sagittal plate, (D) 10-hole miniplate, and (E) two 4-hole miniplates. Biomechanical performance was assessed by compression testing using a universal testing machine. Complementary analyses were performed using strain gauges and digital image correlation. Group 1 in fixation B, C and D demonstrated higher biomechanical resistance than Group 2, however without significance difference. Among the evaluated configurations, subgroup E exhibited the highest resistance values in both experimental conditions. Statistically significant differences were observed among fixation systems within each group (p < 0.05). The fixation systems using two miniplates demonstrated superior biomechanical stability, particularly in mandibular advancements associated with counterclockwise rotational movements. These findings suggest that this fixation strategy may contribute to enhanced postoperative stability in orthognathic surgery involving large mandibular advancements and complex rotational movements.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-06-26
DOI
https://doi.org/10.3390/bioengineering13070745
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Does Counterclockwise Rotation Affect Fixation Stability? An In Vitro Biomechanical Study of Large Mandibular Advancements

G. Klein, Maísa Pereira da Silva, Paulo Matheus Honda Tavares, Daniel Oreadi et al.
Bioengineering
Facial Trauma and Fracture Management
article

Does Counterclockwise Rotation Affect Fixation Stability? An In Vitro Biomechanical Study of Large Mandibular Advancements

G. Klein, Maísa Pereira da Silva, Paulo Matheus Honda Tavares, Daniel Oreadi, Luana Ferreira Oliveira, Bianca Tiemi Uehara Lima, Beethoven Estevão Costa, Paulo Domingos Ribeiro, Osvaldo Magro Filho, Celso Fernando Palmieri Junior
article en

Abstract

The selection of an appropriate fixation system is critical for maintaining postoperative stability after sagittal split ramus osteotomy (SSRO), especially in cases involving large mandibular advancements and counterclockwise rotation, where mechanical stresses may compromise treatment outcomes. This in vitro study evaluated the biomechanical stability of five fixation systems following sagittal split ramus osteotomy (SSRO) under two mandibular advancement conditions. Fifty polyurethane hemimandibles were allocated into two experimental groups: Group 1, submitted to 10-mm linear advancement, and Group 2, submitted to 10-mm advancement associated with 20° counterclockwise rotation. Each group was further divided into five subgroups according to the fixation design employed: (A) conventional straight plate, (B) angled plate, (C) sagittal plate, (D) 10-hole miniplate, and (E) two 4-hole miniplates. Biomechanical performance was assessed by compression testing using a universal testing machine. Complementary analyses were performed using strain gauges and digital image correlation. Group 1 in fixation B, C and D demonstrated higher biomechanical resistance than Group 2, however without significance difference. Among the evaluated configurations, subgroup E exhibited the highest resistance values in both experimental conditions. Statistically significant differences were observed among fixation systems within each group (p < 0.05). The fixation systems using two miniplates demonstrated superior biomechanical stability, particularly in mandibular advancements associated with counterclockwise rotational movements. These findings suggest that this fixation strategy may contribute to enhanced postoperative stability in orthognathic surgery involving large mandibular advancements and complex rotational movements.

BioengineeringVol. 13(7)
Tufts University (US), Louisiana State University in Shreveport (US), Santa Casa Hospital (BR), Faculdade São Leopoldo Mandic (BR), Louisiana State University Health Sciences Center Shreveport (US), Universidade Estadual Paulista (Unesp) (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Openalex Percentile: Top 5%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.