Fabrication of Liquid-Contact Polymeric Membrane Ion-Selective Microelectrodes with a Long Lifetime

The lifetime of polymeric membrane ion-selective microelectrodes is one of the key factors limiting their practical applications. Herein, we report a simple strategy for the fabrication of liquid-contact ion-selective microelectrodes with a long lifetime by increasing the thickness of the polymeric sensing membrane via filling the membrane solution from the back of the micropipette tip. A lead ion-selective microelectrode (Pb2+-ISμE) was used as a model sensor. The geometry of the electrode tip and the amount of membrane solution were optimized. The microelectrode exhibited a Nernstian response slope of 27.4 ± 0.7 mV decade−1 over the concentration range from 1.0 × 10−7 to 1.0 × 10−3 M with a detection limit of 4.2 × 10−8 M. Notably, the response slope of the microelectrode decreased by only 2.2% in 30 days.

Authors

Institutions

Publication Details

Journal
Membranes
Published
2026-06-26
DOI
https://doi.org/10.3390/membranes16070216
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication of Liquid-Contact Polymeric Membrane Ion-Selective Microelectrodes with a Long Lifetime

Longbin Qi, Yuanxin Liu, Wei Qin
Membranes
Analytical Chemistry and Sensors
article

Fabrication of Liquid-Contact Polymeric Membrane Ion-Selective Microelectrodes with a Long Lifetime

Longbin Qi, Yuanxin Liu, Wei Qin
article en

Abstract

The lifetime of polymeric membrane ion-selective microelectrodes is one of the key factors limiting their practical applications. Herein, we report a simple strategy for the fabrication of liquid-contact ion-selective microelectrodes with a long lifetime by increasing the thickness of the polymeric sensing membrane via filling the membrane solution from the back of the micropipette tip. A lead ion-selective microelectrode (Pb2+-ISμE) was used as a model sensor. The geometry of the electrode tip and the amount of membrane solution were optimized. The microelectrode exhibited a Nernstian response slope of 27.4 ± 0.7 mV decade−1 over the concentration range from 1.0 × 10−7 to 1.0 × 10−3 M with a detection limit of 4.2 × 10−8 M. Notably, the response slope of the microelectrode decreased by only 2.2% in 30 days.

MembranesVol. 16(7)
Chinese Academy of Sciences (CN), Institute of Oceanology (CN), Yantai Institute of Coastal Zone Research (CN), Qingdao National Laboratory for Marine Science and Technology (CN), University of Chinese Academy of Sciences (CN)
Department of Science and Technology of Shandong Province, National Natural Science Foundation of China, Ministry of Science and Technology of the People's Republic of China, China Postdoctoral Science Foundation, Natural Science Foundation of Shandong Province, Yantai Science and Technology Bureau, National Key Research and Development Program of China
Openalex Percentile: Top 11%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fabrication of Liquid-Contact Polymeric Membrane Ion-Selective Microelectrodes with a Long Lifetime — Longbin Qi, Yuanxin Liu, et al. · Membranes (2026) | TGRS Research Map | TGRS