Experimental Investigation of Integrated Heat Pipe—Liquid Cooling for a Battery Pack

This study investigates a hybrid tab-cooled heat sink combining sintered-wick copper heat pipes embedded in a high-conductivity aluminum block with computer numerical control machined serpentine liquid cooling channels for a 15-cell lithium-ion battery pack (capacity: 2.5 Ah per cell, parallel connection). Performance was evaluated under constant-current discharge rates (1, 3, and 4 C, where C denotes nominal capacity rating) and automotive drive cycles (Urban Dynamometer Driving Schedule (UDDS), Short Dynamometer Driving Schedule (SDDS), and Worldwide Harmonized Light Vehicles Test Procedure) at coolant flow rates from 0 to 0.5 liters per minute. At 3 C discharge, peak temperature decreased from 81.6 °C to 62.9 °C with active cooling, extending safe operation from 50 to 93% depth-of-discharge before reaching the 60 °C threshold. Temperature variation among cells was reduced by 40%. Dynamic drive cycles showed peak temperature reductions of 19 °C (UDDS) and 22 °C (SDDS). Thermal resistance analysis revealed maximum reductions of 66% (1 C) and 39% (3 C) versus baseline. At low discharge rates, the system is convection-limited, making liquid cooling highly effective. However, at high rates (3–4 C), heat pipe operational limits become the primary constraint, indicating applications requiring sustained operation above 3 C would benefit more from enhanced heat pipe capacity than from increased liquid cooling flow rates.

Authors

Institutions

Publication Details

Journal
Heat Transfer Engineering
Published
2026-06-26
DOI
https://doi.org/10.1080/01457632.2026.2687186
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Investigation of Integrated Heat Pipe—Liquid Cooling for a Battery Pack

Kasavajhula Naga Vasista, K. Harinath Reddy, Bogala Konda Reddy, C. Balaji
Heat Transfer Engineering
Heat Transfer and Boiling Studies
article

Experimental Investigation of Integrated Heat Pipe—Liquid Cooling for a Battery Pack

Kasavajhula Naga Vasista, K. Harinath Reddy, Bogala Konda Reddy, C. Balaji
article en

Abstract

This study investigates a hybrid tab-cooled heat sink combining sintered-wick copper heat pipes embedded in a high-conductivity aluminum block with computer numerical control machined serpentine liquid cooling channels for a 15-cell lithium-ion battery pack (capacity: 2.5 Ah per cell, parallel connection). Performance was evaluated under constant-current discharge rates (1, 3, and 4 C, where C denotes nominal capacity rating) and automotive drive cycles (Urban Dynamometer Driving Schedule (UDDS), Short Dynamometer Driving Schedule (SDDS), and Worldwide Harmonized Light Vehicles Test Procedure) at coolant flow rates from 0 to 0.5 liters per minute. At 3 C discharge, peak temperature decreased from 81.6 °C to 62.9 °C with active cooling, extending safe operation from 50 to 93% depth-of-discharge before reaching the 60 °C threshold. Temperature variation among cells was reduced by 40%. Dynamic drive cycles showed peak temperature reductions of 19 °C (UDDS) and 22 °C (SDDS). Thermal resistance analysis revealed maximum reductions of 66% (1 C) and 39% (3 C) versus baseline. At low discharge rates, the system is convection-limited, making liquid cooling highly effective. However, at high rates (3–4 C), heat pipe operational limits become the primary constraint, indicating applications requiring sustained operation above 3 C would benefit more from enhanced heat pipe capacity than from increased liquid cooling flow rates.

Heat Transfer Engineering
Indian Institute of Technology Madras (IN), Yogi Vemana University (IN)
Sustainable cities and communities
Openalex Percentile: Top 12%
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experimental Investigation of Integrated Heat Pipe—Liquid Cooling for a Battery Pack — Kasavajhula Naga Vasista, K. Harinath Reddy, et al. · Heat Transfer Engineering (2026) | TGRS Research Map | TGRS