LumbarSR: A Paired Clinical CT and Photon-Counting Micro-CT Dataset for Human Lumbar Vertebrae

Low back pain affects hundreds of millions of people and is associated with degenerative changes in the lumbar spine. Trabecular bone microarchitecture change is a reasonable contributor to low back pain, but it remains largely invisible on routine clinical CT because typical voxel sizes (500 to 1000 μm) are insufficient to resolve trabeculae (about 100-200 μm). We present LumbarSR, a paired and registered dataset of 30 human lumbar vertebral specimens scanned with a photon-counting micro-CT (Micro-PCCT) reference at 105 μm isotropic resolution and with a standard clinical CT system under eight acquisition configurations formed by the factorial combination of two in-plane resolutions (195 and 586 μm), two slice thicknesses (500 μm and 1000 μm), and two reconstruction kernels (bone and soft tissue). Clinical CT volumes are rigidly registered to the Micro-PCCT reference using ANTs-based alignment and resampled to a common voxel grid, enabling voxel-wise evaluation and supervised learning. LumbarSR provides data in both original DICOM and registered NIfTI volumes with a consistent directory structure and specimen identifiers. We provide baseline evaluations using whole-image and masked image-quality metrics, trabecular morphometry against the Micro-PCCT reference, and super-resolution benchmarks based on interpolation and deep learning methods. LumbarSR is intended to support the development and evaluation of super-resolution methods for lumbar vertebra CT and related analyses of trabecular level structure. Because specimens were de-identified dry teaching specimens without available clinical histories or demographic metadata, LumbarSR should be interpreted as a paired imaging and benchmarking resource rather than a clinically labeled cohort.

Authors

Institutions

Publication Details

Journal
Scientific Data
Published
2026-06-26
DOI
https://doi.org/10.1038/s41597-026-07748-5
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

LumbarSR: A Paired Clinical CT and Photon-Counting Micro-CT Dataset for Human Lumbar Vertebrae

Zhenzhen Cao, Shenyan Zong, Mengfei Wang, Zhu J et al.
Scientific Data
Advanced X-ray and CT Imaging
article

LumbarSR: A Paired Clinical CT and Photon-Counting Micro-CT Dataset for Human Lumbar Vertebrae

Zhenzhen Cao, Shenyan Zong, Mengfei Wang, Zhu J, Li Y, Ruipeng Zhang, Xinyu Song, Xuefei Hu, Ping Wang, Dan Wang
article en

Abstract

Low back pain affects hundreds of millions of people and is associated with degenerative changes in the lumbar spine. Trabecular bone microarchitecture change is a reasonable contributor to low back pain, but it remains largely invisible on routine clinical CT because typical voxel sizes (500 to 1000 μm) are insufficient to resolve trabeculae (about 100-200 μm). We present LumbarSR, a paired and registered dataset of 30 human lumbar vertebral specimens scanned with a photon-counting micro-CT (Micro-PCCT) reference at 105 μm isotropic resolution and with a standard clinical CT system under eight acquisition configurations formed by the factorial combination of two in-plane resolutions (195 and 586 μm), two slice thicknesses (500 μm and 1000 μm), and two reconstruction kernels (bone and soft tissue). Clinical CT volumes are rigidly registered to the Micro-PCCT reference using ANTs-based alignment and resampled to a common voxel grid, enabling voxel-wise evaluation and supervised learning. LumbarSR provides data in both original DICOM and registered NIfTI volumes with a consistent directory structure and specimen identifiers. We provide baseline evaluations using whole-image and masked image-quality metrics, trabecular morphometry against the Micro-PCCT reference, and super-resolution benchmarks based on interpolation and deep learning methods. LumbarSR is intended to support the development and evaluation of super-resolution methods for lumbar vertebra CT and related analyses of trabecular level structure. Because specimens were de-identified dry teaching specimens without available clinical histories or demographic metadata, LumbarSR should be interpreted as a paired imaging and benchmarking resource rather than a clinically labeled cohort.

Scientific Data
University of Shanghai for Science and Technology (CN), Donghua University (CN), Shanghai Jiao Tong University (CN), Kunming Medical University (CN), Tarim University (CN), Shanghai Sixth People's Hospital (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 12%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.