A fully optimized deep learning framework for explainable and efficient kidney stone detection in computed tomography imaging

PURPOSE: To develop and rigorously evaluate a hyperparameter-optimized custom convolutional neural network for kidney stone detection on axial computed tomography (CT) and to compare it, under matched optimization conditions, with widely used pretrained backbones, emphasizing statistical reliability, computational efficiency, and cross-institutional generalization. METHODS: A custom convolutional neural network with residual blocks was trained on 3,364 axial CT slices (Stone n = 1,577; Non-stone n = 1,787) under a stratified 70/15/15 split. The same Bayesian hyperparameter optimization (1,000 trials per architecture, tree-structured Parzen estimator) was applied uniformly to the proposed model and six pretrained backbones (ResNet101, DenseNet121, EfficientNetB3, MobileNetV3Large, VGG16, Xception). Robustness was characterized by stratified five-fold cross-validation, ten repeated fixed-split runs with controlled seeds, and 95% confidence intervals. External validation used an independent Bangladesh CT cohort (4,121 slices). Interpretability was probed with Grad-CAM++. RESULTS: The proposed model and ResNet101 jointly achieved the best test performance (accuracy 0.9960, F1 0.9957, ROC-AUC ≥ 0.9995). The proposed model attained the lowest single-sample inference latency (2.24 ms; 1.5-53× faster than baselines) with 1.53 M parameters (2.3-28× fewer). Five-fold cross-validation gave Macro-F1 0.9856 ± 0.0036; the Friedman test confirmed significant cross-architecture differences (p < 0.001). 20% in-domain calibration recovered F1 to 0.9806 on the external cohort. Grad-CAM + + activations were anatomically plausible. CONCLUSION: Custom architecture search under a unified Bayesian protocol can match the ceiling of fully-optimized pretrained backbones at a fraction of their computational cost. Methodologically consistent benchmarking, not peak-accuracy reporting, is essential for clinically deployable kidney stone detection.

Authors

Institutions

Publication Details

Journal
Abdominal Radiology
Published
2026-06-27
DOI
https://doi.org/10.1007/s00261-026-05640-9
Primary Topic
Kidney Stones and Urolithiasis Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A fully optimized deep learning framework for explainable and efficient kidney stone detection in computed tomography imaging

U. Yavuzhan Caskurlu, Halit Bakır, Metin Zontul
Abdominal Radiology
Kidney Stones and Urolithiasis Treatments
article

A fully optimized deep learning framework for explainable and efficient kidney stone detection in computed tomography imaging

U. Yavuzhan Caskurlu, Halit Bakır, Metin Zontul
article en

Abstract

PURPOSE: To develop and rigorously evaluate a hyperparameter-optimized custom convolutional neural network for kidney stone detection on axial computed tomography (CT) and to compare it, under matched optimization conditions, with widely used pretrained backbones, emphasizing statistical reliability, computational efficiency, and cross-institutional generalization. METHODS: A custom convolutional neural network with residual blocks was trained on 3,364 axial CT slices (Stone n = 1,577; Non-stone n = 1,787) under a stratified 70/15/15 split. The same Bayesian hyperparameter optimization (1,000 trials per architecture, tree-structured Parzen estimator) was applied uniformly to the proposed model and six pretrained backbones (ResNet101, DenseNet121, EfficientNetB3, MobileNetV3Large, VGG16, Xception). Robustness was characterized by stratified five-fold cross-validation, ten repeated fixed-split runs with controlled seeds, and 95% confidence intervals. External validation used an independent Bangladesh CT cohort (4,121 slices). Interpretability was probed with Grad-CAM++. RESULTS: The proposed model and ResNet101 jointly achieved the best test performance (accuracy 0.9960, F1 0.9957, ROC-AUC ≥ 0.9995). The proposed model attained the lowest single-sample inference latency (2.24 ms; 1.5-53× faster than baselines) with 1.53 M parameters (2.3-28× fewer). Five-fold cross-validation gave Macro-F1 0.9856 ± 0.0036; the Friedman test confirmed significant cross-architecture differences (p < 0.001). 20% in-domain calibration recovered F1 to 0.9806 on the external cohort. Grad-CAM + + activations were anatomically plausible. CONCLUSION: Custom architecture search under a unified Bayesian protocol can match the ceiling of fully-optimized pretrained backbones at a fraction of their computational cost. Methodologically consistent benchmarking, not peak-accuracy reporting, is essential for clinically deployable kidney stone detection.

Abdominal Radiology
Sivas State Hospital (TR)
Sivas Bilim ve Teknoloji Üniversitesi
Openalex Percentile: Top 7%
Kidney Stones and Urolithiasis Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.