Magnetic Compression Anastomosis With Immediate Luminal Patency in Colorectal Surgery: First-in-Human Safety and Feasibility Evaluation of a Self-forming Magnet System

BACKGROUND: Classical colorectal anastomoses performed with sutures or staples rely on tissue penetration, which may serve as a nidus for microabscess formation and contribute to anastomotic leakage. Magnetic compression anastomosis offers a completely non-penetrating alternative for tissue approximation. However, earlier magnetic compression anastomosis systems required delayed luminal patency, rendering them unsuitable for colorectal surgery where immediate bowel continuity is essential. IMPACT OF INNOVATION: A novel magnetic compression system engineered to maintain immediate luminal patency has been developed, overcoming a key limitation of prior magnetic compression anastomosis platforms. This innovation enables intracorporeal colorectal anastomosis using a non-penetrating technique compatible with minimally invasive surgery and may represent a biologically distinct approach to anastomotic healing. TECHNOLOGY MATERIALS AND METHODS: This was a first-in-human, early-phase prospective safety and feasibility study conducted at a single tertiary referral center for minimally invasive colorectal surgery. A consecutive series of 25 adult patients undergoing elective laparoscopic or robotic colorectal resection received intracorporeal anastomosis using a self-forming magnetic compression system following a standardized operative protocol. The primary outcome was anastomotic leak within 30 postoperative days. Secondary outcomes included technical feasibility, adverse events, device performance, and anastomotic patency assessed during 60 days of follow-up. PRELIMINARY RESULTS: All procedures were completed using minimally invasive techniques without conversion to open surgery. Intracorporeal magnetic compression anastomoses were technically successful in all cases. No anastomotic leaks were observed within 30 days. Adverse events occurred in 6 patients (24%), all classified as Clavien–Dindo Grade I and managed conservatively. Postoperative imaging and/or endoscopic evaluation demonstrated complete anastomotic patency and healing in all patients, with no evidence of stenosis, obstruction, or delayed transit during 60 days of follow-up. CONCLUSIONS AND FUTURE DIRECTIONS: In this first-in-human experience, intracorporeal magnetic compression colorectal anastomosis using the self-forming system was feasible and demonstrated a favorable short-term safety profile, with consistent anastomotic patency and absence of leaks. Although limited by small sample size, single-center design, and lack of a comparator group, these results support further prospective and comparative studies to define the role of magnetic compression anastomosis in colorectal surgery. See New Technology Video . ClinicalTrials.gov Registration ID: NCT06915818

Authors

Institutions

Publication Details

Journal
Diseases of the Colon & Rectum
Published
2026-06-26
DOI
https://doi.org/10.1097/dcr.0000000000004309
Primary Topic
Colorectal Cancer Surgical Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic Compression Anastomosis With Immediate Luminal Patency in Colorectal Surgery: First-in-Human Safety and Feasibility Evaluation of a Self-forming Magnet System

Mohit Bhandari, Manoel Galvao Neto, Manoj Reddy, Winnie Mathur et al.
Diseases of the Colon & Rectum
Colorectal Cancer Surgical Treatments
article

Magnetic Compression Anastomosis With Immediate Luminal Patency in Colorectal Surgery: First-in-Human Safety and Feasibility Evaluation of a Self-forming Magnet System

Mohit Bhandari, Manoel Galvao Neto, Manoj Reddy, Winnie Mathur, Andrew Nguyen, Antonio Caycedo-Marulanda
article en

Abstract

BACKGROUND: Classical colorectal anastomoses performed with sutures or staples rely on tissue penetration, which may serve as a nidus for microabscess formation and contribute to anastomotic leakage. Magnetic compression anastomosis offers a completely non-penetrating alternative for tissue approximation. However, earlier magnetic compression anastomosis systems required delayed luminal patency, rendering them unsuitable for colorectal surgery where immediate bowel continuity is essential. IMPACT OF INNOVATION: A novel magnetic compression system engineered to maintain immediate luminal patency has been developed, overcoming a key limitation of prior magnetic compression anastomosis platforms. This innovation enables intracorporeal colorectal anastomosis using a non-penetrating technique compatible with minimally invasive surgery and may represent a biologically distinct approach to anastomotic healing. TECHNOLOGY MATERIALS AND METHODS: This was a first-in-human, early-phase prospective safety and feasibility study conducted at a single tertiary referral center for minimally invasive colorectal surgery. A consecutive series of 25 adult patients undergoing elective laparoscopic or robotic colorectal resection received intracorporeal anastomosis using a self-forming magnetic compression system following a standardized operative protocol. The primary outcome was anastomotic leak within 30 postoperative days. Secondary outcomes included technical feasibility, adverse events, device performance, and anastomotic patency assessed during 60 days of follow-up. PRELIMINARY RESULTS: All procedures were completed using minimally invasive techniques without conversion to open surgery. Intracorporeal magnetic compression anastomoses were technically successful in all cases. No anastomotic leaks were observed within 30 days. Adverse events occurred in 6 patients (24%), all classified as Clavien–Dindo Grade I and managed conservatively. Postoperative imaging and/or endoscopic evaluation demonstrated complete anastomotic patency and healing in all patients, with no evidence of stenosis, obstruction, or delayed transit during 60 days of follow-up. CONCLUSIONS AND FUTURE DIRECTIONS: In this first-in-human experience, intracorporeal magnetic compression colorectal anastomosis using the self-forming system was feasible and demonstrated a favorable short-term safety profile, with consistent anastomotic patency and absence of leaks. Although limited by small sample size, single-center design, and lack of a comparator group, these results support further prospective and comparative studies to define the role of magnetic compression anastomosis in colorectal surgery. See New Technology Video . ClinicalTrials.gov Registration ID: NCT06915818

Diseases of the Colon & Rectum
University of Central Florida (US), Devi Ahilya Vishwavidyalaya (IN), Orlando Health (US), Queen's University (CA), Orlando Regional Medical Center (US), Mohak Hitech Speciality Hospital (IN), Sri Aurobindo Institute of Medical Sciences (IN)
Industry, innovation and infrastructure
Openalex Percentile: Top 8%
Colorectal Cancer Surgical Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.