Diagnostic yield and utilization patterns of head and neck computed tomography angiography

Objectives: This study evaluates the diagnostic yield and utilization patterns of head and neck computed tomography angiography (CTAHN) in screening patients in the emergency department (ED) for blunt cerebrovascular injury. This study was conducted at a Level 1 trauma center serving a large geographical area with a high number of regional transfers. This study evaluates the prevalence of CTAHN overutilization in the ED and examines whether diagnostic yield correlates with adherence to the modified Denver criteria, transfer status, and trauma severity. Material and Methods: A retrospective chart review was conducted of patients presenting to the ED between January 01, 2021, and December 31, 2023. Patients over the age of 16 were included in this study if they presented with blunt traumatic injury and subsequently underwent CTAHN or neck CTA (CTAN) imaging during their ED evaluation. A multivariable regression analysis was performed to evaluate the association between CTA yield and factors including patient transfer status, trauma severity designation, and adherence to the modified Denver criteria. Results: A total of 643 patients met the inclusion criteria. A substantial proportion (74.2%) of CTAHN and CTAN examinations yielded negative results, with significant correlation to nonadherence to the modified Denver criteria. We found no significant association between CTAHN yield and transfer status or trauma level designation. Of the patients found to have trauma related actionable findings, 71.8% had adherence to the modified Denver criteria during triage screening. Conclusion: A high proportion of CTAHN and CTAN studies ordered from the ED yield low-value diagnostic results, with overutilization closely linked to nonadherence to the modified Denver criteria. Our findings carry important implications for quality improvement efforts, including unnecessary radiation exposure to patients and reduced efficiency in the ED. Enhanced guideline compliance may serve as a modifiable target to reduce diagnostic imaging overutilization.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Imaging Science
Published
2026-06-26
DOI
https://doi.org/10.25259/jcis_275_2025
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic yield and utilization patterns of head and neck computed tomography angiography

Roy Jacob, K. Nagy, Laszlo Nagy, Jantzen Brandt Orton et al.
Journal of Clinical Imaging Science
Radiation Dose and Imaging
article

Diagnostic yield and utilization patterns of head and neck computed tomography angiography

Roy Jacob, K. Nagy, Laszlo Nagy, Jantzen Brandt Orton, Abdul Awal
article en

Abstract

Objectives: This study evaluates the diagnostic yield and utilization patterns of head and neck computed tomography angiography (CTAHN) in screening patients in the emergency department (ED) for blunt cerebrovascular injury. This study was conducted at a Level 1 trauma center serving a large geographical area with a high number of regional transfers. This study evaluates the prevalence of CTAHN overutilization in the ED and examines whether diagnostic yield correlates with adherence to the modified Denver criteria, transfer status, and trauma severity. Material and Methods: A retrospective chart review was conducted of patients presenting to the ED between January 01, 2021, and December 31, 2023. Patients over the age of 16 were included in this study if they presented with blunt traumatic injury and subsequently underwent CTAHN or neck CTA (CTAN) imaging during their ED evaluation. A multivariable regression analysis was performed to evaluate the association between CTA yield and factors including patient transfer status, trauma severity designation, and adherence to the modified Denver criteria. Results: A total of 643 patients met the inclusion criteria. A substantial proportion (74.2%) of CTAHN and CTAN examinations yielded negative results, with significant correlation to nonadherence to the modified Denver criteria. We found no significant association between CTAHN yield and transfer status or trauma level designation. Of the patients found to have trauma related actionable findings, 71.8% had adherence to the modified Denver criteria during triage screening. Conclusion: A high proportion of CTAHN and CTAN studies ordered from the ED yield low-value diagnostic results, with overutilization closely linked to nonadherence to the modified Denver criteria. Our findings carry important implications for quality improvement efforts, including unnecessary radiation exposure to patients and reduced efficiency in the ED. Enhanced guideline compliance may serve as a modifiable target to reduce diagnostic imaging overutilization.

Journal of Clinical Imaging ScienceVol. 16
Texas Tech University (US), University Medical Center (US), Texas Tech University Health Sciences Center (US)
Openalex Percentile: Top 6%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.