Development loop-mediated isothermal amplification assay for detection of enteropathogenic Escherichia coli (EPEC)

BACKGROUND: Enteropathogenic Escherichia coli (EPEC) is a major etiological agent of persistent diarrhea in pediatric and adult population globally and it is a leading cause of infant mortality in developing countries. Bacterial culture and biochemical assays are insufficient for accurately identifying EPEC strains. In contrast, PCR serves as a major molecular diagnostic method for EPEC. However, the application of PCR is limited due to high cost, time taking and technical requirements. METHOD AND RESULTS: In this study loop mediated isothermal amplification LAMP) was developed for rapid, specific, easy and resource-friendly detection of EPEC. The LAMP assay was developed by designing specific lamp primers targeting eae genes, in combination with stx1 and stx2 lamp primers to enable EPEC detection. The reaction mixture, which contained 2.5 µL of isothermal amplification buffer, 10 mM of MgSO4 solution, 1.4 mM of dNTPs, 1.8 mM of FIP and BIP, 0.4 mM of F3 and B3, 0.2 mM of LB, 8U of Bst polymerase, and 2.0 µL of the target DNA template, was incubated at 62 C0 for 60 minutes. The designed lamp assay's performance was assessed utilizing 60 bacterial trains that were isolated locally. The assay attained 100% efficiency (60/60), 100% sensitivity (10/10), and 100% specificity (50/50). Furthermore, both the positive and negative predictive scores were 100%. Up to 0.05 pg of DNA could be detected in each reaction using the developed LAMP test. The traditional PCR, on the other hand, showed a detection limit of 5 pg/reaction. Additionally, the developed LAMP assay was able to detect up to 7 x 102 cfu/g stool in a spiked stool sample. PCR, however, can identify up to 7 x 104 cfu/g of stool. Notably, compared to conventional PCR, the LAMP assay has a 100-fold greater sensitivity. The result obtained from LAMP and PCR tests showed a perfect agreement with a kappa value of 1 (k = 1). CONCLUSION: The developed LAMP assay demonstrated promising performance for the detection of EPEC under controlled laboratory conditions, offering a rapid and straightforward alternative to conventional diagnostic methods. Clinical validation using patient stool sample and further studies with larger sample sets are needed to fully establish the assay's performance and support its broader clinical application.

Authors

Institutions

Publication Details

Journal
Molecular Biology Reports
Published
2026-06-26
DOI
https://doi.org/10.1007/s11033-026-12206-x
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development loop-mediated isothermal amplification assay for detection of enteropathogenic Escherichia coli (EPEC)

Tesfaye Sisay Tessema, Alazar Amare Amdiyee
Molecular Biology Reports
Biosensors and Analytical Detection
article

Development loop-mediated isothermal amplification assay for detection of enteropathogenic Escherichia coli (EPEC)

Tesfaye Sisay Tessema, Alazar Amare Amdiyee
article en

Abstract

BACKGROUND: Enteropathogenic Escherichia coli (EPEC) is a major etiological agent of persistent diarrhea in pediatric and adult population globally and it is a leading cause of infant mortality in developing countries. Bacterial culture and biochemical assays are insufficient for accurately identifying EPEC strains. In contrast, PCR serves as a major molecular diagnostic method for EPEC. However, the application of PCR is limited due to high cost, time taking and technical requirements. METHOD AND RESULTS: In this study loop mediated isothermal amplification LAMP) was developed for rapid, specific, easy and resource-friendly detection of EPEC. The LAMP assay was developed by designing specific lamp primers targeting eae genes, in combination with stx1 and stx2 lamp primers to enable EPEC detection. The reaction mixture, which contained 2.5 µL of isothermal amplification buffer, 10 mM of MgSO4 solution, 1.4 mM of dNTPs, 1.8 mM of FIP and BIP, 0.4 mM of F3 and B3, 0.2 mM of LB, 8U of Bst polymerase, and 2.0 µL of the target DNA template, was incubated at 62 C0 for 60 minutes. The designed lamp assay's performance was assessed utilizing 60 bacterial trains that were isolated locally. The assay attained 100% efficiency (60/60), 100% sensitivity (10/10), and 100% specificity (50/50). Furthermore, both the positive and negative predictive scores were 100%. Up to 0.05 pg of DNA could be detected in each reaction using the developed LAMP test. The traditional PCR, on the other hand, showed a detection limit of 5 pg/reaction. Additionally, the developed LAMP assay was able to detect up to 7 x 102 cfu/g stool in a spiked stool sample. PCR, however, can identify up to 7 x 104 cfu/g of stool. Notably, compared to conventional PCR, the LAMP assay has a 100-fold greater sensitivity. The result obtained from LAMP and PCR tests showed a perfect agreement with a kappa value of 1 (k = 1). CONCLUSION: The developed LAMP assay demonstrated promising performance for the detection of EPEC under controlled laboratory conditions, offering a rapid and straightforward alternative to conventional diagnostic methods. Clinical validation using patient stool sample and further studies with larger sample sets are needed to fully establish the assay's performance and support its broader clinical application.

Molecular Biology ReportsVol. 53(1)
Addis Ababa Science and Technology University (ET), Dilla University (ET), Addis Ababa University (ET)
Addis Ababa University
Openalex Percentile: Top 12%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.