Reducing Surgical Instrument Contamination Through Multidisciplinary Quality Improvement: A Systems Approach at an Academic Medical Center

BACKGROUND: In early 2025, OU Health identified an increase in contaminated surgical instrument sets reaching the operating room (OR). Contaminants, including bioburden, hair, holes in wrapping, debris, and wet sets, posed risks to patient safety, workflow efficiency, and OR productivity, suggesting systemic deficiencies across the sterile processing department (SPD) and perioperative workflow. METHODS: We convened a multidisciplinary quality-improvement team comprising administrators, surgeons, nurses, scrub technicians, SPD technicians, and quality specialists. Using the 8-Step methodology, we conducted root cause analysis, process mapping, and longitudinal data tracking. Interventions included standardized point-of-use cleaning, enhanced SPD personal protective equipment and gowning practices, washer maintenance, adoption of heavier wrapping materials, containerization of high-risk sets, limiting tray weight, removal of static-attracting materials, and targeted staff education. RESULTS: From July 1, 2025, through January 31, 2026, 388 contamination events were recorded across service lines. Neurosurgery accounted for 36% (136 events) of all events. Common contamination types were holes (113 events), debris (98), bioburden (51), and filter defects (28); hair (20), wet sets (15), and improper disassembly (15) were less common but clinically significant. Temporal analysis demonstrated intermittent short-term improvements but persistent recurrence across contamination types. Contaminated sets contributed to 57% of all documented OR delays, totaling 2851 minutes. Estimated direct costs were $176 762; projected annual costs were $589 042. CONCLUSIONS: Contaminated surgical instrument sets represented a recurrent systems-level failure. Institution-wide efforts, including multidisciplinary collaboration, structured quality-improvement methodology, and targeted interventions, produced measurable improvements. Continued monitoring, workforce competency reinforcement, and system redesign are needed to mitigate future risk.

Authors

Institutions

Publication Details

Journal
American Journal of Medical Quality
Published
2026-06-26
DOI
https://doi.org/10.1097/jmq.0000000000000320
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing Surgical Instrument Contamination Through Multidisciplinary Quality Improvement: A Systems Approach at an Academic Medical Center

N L Dao, Emily Tally, Lisa Case, Andrew Jea et al.
American Journal of Medical Quality
Medical Device Sterilization and Disinfection
article

Reducing Surgical Instrument Contamination Through Multidisciplinary Quality Improvement: A Systems Approach at an Academic Medical Center

N L Dao, Emily Tally, Lisa Case, Andrew Jea, Kaitlin Marshall, Kamga Nkouli, Wendy Seiger, James Lutz, Robert Rusco, Michael Morrey
article en

Abstract

BACKGROUND: In early 2025, OU Health identified an increase in contaminated surgical instrument sets reaching the operating room (OR). Contaminants, including bioburden, hair, holes in wrapping, debris, and wet sets, posed risks to patient safety, workflow efficiency, and OR productivity, suggesting systemic deficiencies across the sterile processing department (SPD) and perioperative workflow. METHODS: We convened a multidisciplinary quality-improvement team comprising administrators, surgeons, nurses, scrub technicians, SPD technicians, and quality specialists. Using the 8-Step methodology, we conducted root cause analysis, process mapping, and longitudinal data tracking. Interventions included standardized point-of-use cleaning, enhanced SPD personal protective equipment and gowning practices, washer maintenance, adoption of heavier wrapping materials, containerization of high-risk sets, limiting tray weight, removal of static-attracting materials, and targeted staff education. RESULTS: From July 1, 2025, through January 31, 2026, 388 contamination events were recorded across service lines. Neurosurgery accounted for 36% (136 events) of all events. Common contamination types were holes (113 events), debris (98), bioburden (51), and filter defects (28); hair (20), wet sets (15), and improper disassembly (15) were less common but clinically significant. Temporal analysis demonstrated intermittent short-term improvements but persistent recurrence across contamination types. Contaminated sets contributed to 57% of all documented OR delays, totaling 2851 minutes. Estimated direct costs were $176 762; projected annual costs were $589 042. CONCLUSIONS: Contaminated surgical instrument sets represented a recurrent systems-level failure. Institution-wide efforts, including multidisciplinary collaboration, structured quality-improvement methodology, and targeted interventions, produced measurable improvements. Continued monitoring, workforce competency reinforcement, and system redesign are needed to mitigate future risk.

American Journal of Medical QualityVol. 41(4)
OU Health, University of Oklahoma Health Sciences Center (US), University of Oklahoma (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 8%
Medical Device Sterilization and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.