Modeling air source heat pumps under severe frosting conditions and evaluating performance during demand response events

Managing the electric demand of heat pumps on the coldest days is an important aspect of congested low voltage grids. Specifically, severe frosting of the evaporator deteriorates system performance. Contemporary models are limited in representing severe frosting conditions. To understand the potential impacts of these conditions on the grid, a new model for the initiation and operation of defrost cycles that incorporates relative humidity, outdoor temperature, and heat pump loading was developed. To investigate regular and flexible operation of the system, various heating system design parameters were simulated. The simulations show that the heat pump was able to coordinate all tasks without additional electric resistive heating. Furthermore, the impact of a flexibility request on the amount of defrost cycles was found to be negligible. Finally, the results highlight the need to consider both efficiency and flexibility during the design process.

Authors

Institutions

Publication Details

Journal
Electric Power Systems Research
Published
2026-06-26
DOI
https://doi.org/10.1016/j.epsr.2026.113520
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling air source heat pumps under severe frosting conditions and evaluating performance during demand response events

Lisanne Havinga, Jeroen J. Markus, Koen Kok, Christina Papadimitriou
Electric Power Systems Research
Heat Transfer and Optimization
article

Modeling air source heat pumps under severe frosting conditions and evaluating performance during demand response events

Lisanne Havinga, Jeroen J. Markus, Koen Kok, Christina Papadimitriou
article en

Abstract

Managing the electric demand of heat pumps on the coldest days is an important aspect of congested low voltage grids. Specifically, severe frosting of the evaporator deteriorates system performance. Contemporary models are limited in representing severe frosting conditions. To understand the potential impacts of these conditions on the grid, a new model for the initiation and operation of defrost cycles that incorporates relative humidity, outdoor temperature, and heat pump loading was developed. To investigate regular and flexible operation of the system, various heating system design parameters were simulated. The simulations show that the heat pump was able to coordinate all tasks without additional electric resistive heating. Furthermore, the impact of a flexibility request on the amount of defrost cycles was found to be negligible. Finally, the results highlight the need to consider both efficiency and flexibility during the design process.

Electric Power Systems ResearchVol. 262
Eindhoven University of Technology (NL)
Technische Universiteit Eindhoven
Affordable and clean energy
Openalex Percentile: Top 12%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.